KLV-40S410A - Sony TV Service Manual (repair manual). Page 10

Read Sony KLV-40S410A Service Manual online

10
KLV-40S410A
KLV-40S410A
SELF-DIAGNOSTIC FUNCTION
Self Diagnosis
Supported model
The units in this manual contain a self-diagnostic function. If an error occurs, the STANDBY LED indicator will automatically begin to fl ash. The number 
of times the LED fl ashes translates to a probable source of the problem. A defi nition of the STANDBY LED fl ash indicators is listed in the instruction 
manual for the user’s knowledge and reference. If an error symptom cannot be reproduced, the Remote Commander can be used to review the failure 
occurrence data stored in memory to reveal past problems and how often these problems occur.
1. Diagnostic Test Indicators
When an error occurs, the STANDBY LED indicator will fl ash a set number of times to indicate the possible cause of the problem. If there is more than 
one error, the indicator will identify the fi rst of the problem areas.
Control Buttons
Description of LED Indictors
LED
LED Type
PIC OFF/TIMER Green or Orange  * Lights up in orange when the timer is set.
LED
LED
  When the time is set, the LED remains lit 
  even when the TV is turned off.
* Lights up in green when Backlight is activated.
* If LED blinks continuously, this may indicate
  that the TV needs servicing.
* Lights up in green when the TV set is on
* Lights up in red when TV is in standby mode
Description
STANDBY LED
POWER LED
Green LED
Red LED
2 times
5 times
LED ON 0.3 sec.
LED OFF 0.3 sec.
LED OFF
3 sec.
Page of 73
Display

Click on the first or last page to see other KLV-40S410A service manuals if exist.