When safety shutdown occurs, LED display reports the cause by using the Lighting patterns as indicated below. Since there are
various failure items in WAX model. Light blinking is used so that shutdown causes can be judged from the number of blinking times.
The items corresponding to the number of blinking times are indicated as follows
Example : The figure above shows a LED display when SHUTDOWN is caused by an DC. Alert 2. It repeats flashing for a
specified number of times in 0.3 sec/cycle, has a 2 seconds interval of lighting-off, and again repeats flashing for the
same number of times. Please note that a 2 seconds interval of lighting-off is fixed regardless of abnormal state types.
2.0 sec
2.0 sec
0.3 sec
0.3 sec
STBY-LED
MONITORING ITEMS
Possible Cause / Detected Symptoms
Flash times
2 times
Main voltage trouble (REG12V)
 Power supply voltage error.
3 times
DC_ALERT 1 (D.3.3V)
 Confirm the voltage if the right voltage doesn’t appear
  about D3. 3V,VDDMQO(=2.5V)
 If it is D3. 3V,VDDMQO(=2.5V), confirm about 3.3V input
  IC7001 5th Pin and F7000 is not open.
 If it is VD1.8V, confirm about 3.3V input IC7002 5th Pin
  and F7000 is not open.
 If it is VD1.8V, confirm about 3.3V input IC7000 12th Pin
  and PS7000 is not open.
4 times
DC_ALERT 2 (FE3.3V)
5 times
DC_ALERT 3 (PANEL 12V)
 Confirm, the voltage of REG12V is about 12V.
 If no voltage is on REG12V, Confirm R3031, R3034,
  R3037 is mounted.
 If no voltage is on REG12V, Confirm REG12V is short-
  circuits in GND.
 If REG12V is not short-circuits in GND, change PWB to
  new one.
6 times
BackLight trouble (PANE_DET=0V)
 Confirm, about D3. 3 input to Q4014/Q4015.
 If 6 times, change backlight-board.