KLV-26NX400, KLV-32NX400, KLV-32NX500, KLV-40NX500 (serv.man2) - Sony TV Service Manual (repair manual). Page 6

Read Sony KLV-26NX400 / KLV-32NX400 / KLV-32NX500 / KLV-40NX500 (serv.man2) Service Manual online

– 5 –
KLV-26,32 NX400(S/B), 26,32 NX400(S/B)/S, 32,40 NX500
RM-GA018
SECTION 2
SELF DIAGNOSTIC FUNCTION
2-4. LED Pattern
When safety shutdown occurs, Standby LED display reports the
cause by using the lightning patterns as indicated below.
Example:
The figure above shows LED display when
SHUTDOWN is caused by Balancer Error. It repeats
flashing for a specified number of times in 0.5sec/
cycle and has a 3 seconds interval of lighting off.
Please note that a 3 seconds interval of lighting off
is fixed regardless of abnormal state types.
3.0 sec
3.0 sec
0.5 sec
0.5 sec
2-1. Overview of Control Buttons
2-2. LED Display Specification
2-3. LED Display Control
PROG
Power
Programme
Volume
Input select/
Enter
Menu
Remote
Sensor
Picture Off/
Timer indicator
Standby
indicator
Power
indicator
 LED Typ e
       Description
Remark
Status
Display
Power LED
 
Remark
 POWER
  
Green: LED
    Green lights at power ON.
 STANDB
Timer
Y
 
Red: One LED
 
Red lights during standby.
  Orange
  : One LED
     Orange lights 
   during Timer activation.
POWER ON   Green lights
OFF
in a normal state.
STANDBY
OF
OFF
F
Red lights
Red flashes
Microcomputer is
in a sleep state.
Failure
Classify the trouble
causes by the no.
of red blinking.
Standby LED
Microcomputer is
Page of 52