Safety Notes
4) B
t f ll
th
id li
t
t
t
t
d
id
i
1-4. How to Find a Good Earth Ground
1) A cold-water pipe is a guaranteed earth ground; the cover-plate retaining
screw on most AC outlet boxes is also at earth ground.
2) If the retaining screw is to be used as your earth ground, verify that it is at
ground by measuring the resistance between it and a cold-water pipe with an
ohmmeter. The reading should be zero ohms.
3) If a cold-water pipe is not accessible, connect a 60- to 100-watt trouble- light
screw on most AC outlet boxes is also at earth ground.
2) If the retaining screw is to be used as your earth ground, verify that it is at
ground by measuring the resistance between it and a cold-water pipe with an
ohmmeter. The reading should be zero ohms.
3) If a cold-water pipe is not accessible, connect a 60- to 100-watt trouble- light
4) Be sure to follow these guidelines to protect your property and avoid causing
serious injury.
• Carry the TV with an adequate number of people; larger size TVs require
two or more people.
• Correct hand placement while carrying the TV is very important for safety
and to avoid damages.
)
p p
g
(not a neon lamp) between the hot side of the receptacle and the retaining screw.
Try both slots, if necessary, to locate the hot side on the line; the lamp should
light at normal brilliance if the screw is at ground potential (see Figure 3).
Try both slots, if necessary, to locate the hot side on the line; the lamp should
light at normal brilliance if the screw is at ground potential (see Figure 3).
5) Components identified by shading and mark on the exploded views, and
in the parts list are critical for safe operation. Replace these components with
Sony parts whose part numbers appear as shown in this manual or in
supplements published by Sony. Circuit adjustments that are critical
for safe operation are identified in this manual Follow these procedures
!
for safe operation are identified in this manual. Follow these procedures
whenever critical components are replaced or improper operation is suspected.
1-6. Lead Free Information
The circuit boards used in these models have been processed using Lead Free
Solder. The boards are identified by the LF logo located close to the board
d
Solder. The boards are identified by the LF logo located close to the board
d
i
ti
Figure 3. Checking for earth ground.
designation.
1-5. Warnings and Caution
1) These servicing instructions are for use by qualified service personnel only.
2) To reduce the risk of electric shock, do not perform any servicing other than
that contained in the operating instructions unless you are qualified to do so.
3) An isolation transformer should be used during any service to avoid possible
h
k h
d b
f li
h
i
Th
h
i
f thi
i
i di
tl
Figure 4: LF
Logo
Logo
Figure 5: LF logo on circuit board
6
shock hazard, because of live chassis. The chassis of this receiver is directly
connected to the ac power line.
Click on the first or last page to see other KLV-22BX350 / KLV-26BX350 / KLV-32BX350 / KLV-40BX450 / KLV-46BX450 service manuals if exist.