KLV-21SG2 (serv.man2) - Sony TV Service Manual (repair manual). Page 3

Read Sony KLV-21SG2 (serv.man2) Service Manual online

KLV-21SG2 (UC) 3
LEAKAGE  TEST
The AC leakage from any exposed metal part to earth ground
and from all exposed metal parts to any exposed metal part
having a return to chassis, must not exceed 0.5 mA (500
microamperes).
Leakage current can be measured by any one of three methods.
1. A  commercial  leakage  tester,  such  as  the  Simpson  229  or
RCA WT-540A. Follow the manufacturers’ instructions to
use these instruments.
2. A  battery-operated  AC  milliammeter.  The  Data  Precision
245 digital multimeter is suitable for this job.
3. Measuring the voltage drop across a resistor by means of a
VOM or battery-operated AC voltmeter. The “limit” indica-
tion is 0.75 V, so analog meters must have an accurate low-
voltage  scale.  The  Simpson  250  and  Sanwa  SH-63Trd  are
examples  of  a  passive  VOMs  that  are  suitable.  Nearly  all
battery  operated  digital  multimeters  that  have  a  2  V  AC
range are suitable.  (See Fig. A)
After correcting the original service problem, perform the fol-
lowing safety checks before releasing the set to the customer:
1. Check the area of your repair for unsoldered or poorly-sol-
dered connections. Check the entire board surface for solder
splashes and bridges.
2. Check  the  interboard  wiring  to  ensure  that  no  wires  are
“pinched” or contact high-wattage resistors.
3. Check that all control knobs, shields, covers, ground straps,
and mounting hardware have been replaced. Be absolutely
certain that you have replaced all the insulators.
4. Look for unauthorized replacement parts, particularly tran-
sistors,  that  were  installed  during  a  previous  repair.  Point
them out to the customer and recommend their replacement.
5. Look  for  parts  which,  though  functioning,  show  obvious
signs  of  deterioration.  Point  them  out  to  the  customer  and
recommend their replacement.
6. Check the line cords for cracks and abrasion. Recommend
the replacement of any such line cord to the customer.
7. Check  the  B+  and  HV  to  see  if  they  are  specified  values.
Make sure your instruments are accurate; be suspicious of
your HV meter if sets always have low HV.
8. Check  the  antenna  terminals,  metal  trim,  “metallized”
knobs,  screws,  and  all  other  exposed  metal  parts  for  AC
Leakage. Check leakage as described right.
SAFETY  CHECK-OUT
Fig. A. Using an AC voltmeter to check AC leakage.
1.5 k
0.15
µF
AC
Voltmeter
(0.75 V)
To Exposed Metal
Parts on Set
Earth Ground
CAUTION
These servicing instructions are for use by qualified service 
personnel only. To reduce the risk of electric shock, do 
not perform any servicing other than that contained in the 
operating instructions unless you are qualified to do so.
WARNING!!
An isolation transformer should be used during any service 
to avoid possible shock hazard, because of live chassis. The 
chassis of this receiver is directly connected to the ac power 
line.
!
 
SAFETY-RELATED COMPONENT 
WARNING!!
Components identified by shading and ! mark on the 
schematic diagrams, exploded views, and in the parts list 
are critical for safe operation. Replace these components 
with Sony parts whose part numbers appear as shown 
in this manual or in supplements published by Sony. 
Circuit adjustments that are critical for safe operation are 
identified in this manual. Follow these procedures whenever 
critical components are replaced or improper operation is 
suspected. 
ATTENTION!!
Ces instructions de service sont à l’usage du personnel de 
service qualifié seulement. Pour prévenir le risque de choc 
électrique, ne pas faire l’entretien autre que celui contenu 
dans le Mode d’emploi à moins que vous soyez qualifié faire 
ainsi.
Afin d’eviter tout risque d’electrocution provenant d’un 
chássis sous tension, un transformateur d’isolement doit etre 
utilisé lors de tout dépannage. Le chássis de ce récepteur 
est directement raccordé à l’alimentation du secteur.
ATTENTION AUX COMPOSANTS 
RELATIFS A LA SECURITE!!
Les composants identifies par une trame et par une marque 
!
 sur les schemas de principe, les vues explosees et 
les listes de pieces sont d’une importance critique pour la 
securite du fonctionnement. Ne les remplacer que par des 
composants Sony dont le numero de piece est indique dans 
le present manuel ou dans des supplements publies par 
Sony. Les reglages de circuit dont l’importance est critique 
pour la securite du fonctionnement sont identifies dans le 
present manuel. Suivre ces procedures lors de chaque 
remplacement de composants critiques, ou lorsqu’un 
mauvais fonctionnement suspecte.
Page of 91