KF-E42A10, KF-E50A10 (serv.man5) - Sony TV Service Manual (repair manual). Page 8

Read Sony KF-E42A10 / KF-E50A10 (serv.man5) Service Manual online

9
KF-E42A10/E50A10
KF-E42A10/E50A10
DISPLAY OF POWER/STANDBY OR LAMP LED FLASH COUNT
PUSH OPEN
POWER/STANDBY
POWER
TIMER
LAMP
Indicators
Screen
- One flash is not us ed for s elf- diag nosis.
Number of times LED Flash
Lamp cove r
3 times
Fan
4 times
LED ON : 0.3 sec
LED OFF : 0.3sec
LED OFF
3.0 sec
LED OFF
3.0 sec
Example
Diagnosis
RELEASING THE POWER/STANDBY LED FLASH
Unplug the power cord from the outlet to temporarily stop the POWER/STANDBY lamp from fl ashing.
Self-Diagnostic Screen Display
For failures that are diffi cult to reproduce, or accompany occasional power off and/or picture mute, the Self-Diagnostic screen display is useful to 
specify the cause.
VIEWING THE SELF-DIAGNOSTIC SCREEN
1.  TV must be in standby mode. (Power off).
2.  Press the following buttons on the Remote Commander within a second of each other: 
 
DISPLAY   
Channel 
5      
  Volume  -  
  POWER
 
 
 
 
NOTE:  This differs from the method of accessing service mode which is Volume  +
 
Sample Self-Diagnostic Screen Display
 
SELF CHECK
1 :
LAMP_ERROR
0
2 :
TEMP_ERROR
0
0
2 :
LAMP_TEMP
0
3 :
4 :
LAMP_ COVER
FAN_ERROR
1
5 :
LAMP_DRIVER
6 :
LOWB-ERROR
0
0
7 :
AUDIO_PROT
8 :
D_OVP
0
1
TIME    :  00105H
MODEL:  KF-E50A10
SERIAL:  XXXXXXX
"1" is displayed when an error is detected one or more times
"0" is displayed when no error has been detected
 
NOTE: To refresh the Self Check menu when all the items are not displayed, press  JUMP  on the Remote Commander. 
3.  Proceed to Viewing the Self-Diagnostic Errors.