KF-60DX100K - Sony TV Service Manual (repair manual). Page 27

Read Sony KF-60DX100K Service Manual online

 27 
KF-60DX100K
RM-Y910K
L001OUT
No.
Name
0
OCKPN
Inverts OCK polarity
0 - 1
1
1
OSDCKPN
Inverts OSD CK polarity
0 - 1
0
2
FLENB
Pads the inside of OACTB with fill value
0 - 1
0
3
FLENA
Pads the inside of OACTA with fill value
0 - 1
0
4
MSKB
Pads the outside of OACTB with background value
0 - 1
0
5
ASL
Selects OACT to be outputted
0 - 3
0
6
OVSCYCL
Sets the cycle of output vertical sync signal (OVSB)
0 - 255
85
7
OVSCYCU
Sets the cycle of output vertical sync signal (OVSB)
0 - 15
3
8
OVSDLYEN
OVSDLY enable
0 - 1
1
9
IVSPRN
Disables the propagation of IVS signal to internal OVSB
0 - 1
0
10
OVPOL
Specifies the polarity of output vertical sync signal (OVSB)
0 - 1
0
11
OVSD
Specifies the output timing of OVSB
0 - 3
0
12
OVSWD
Specifies the number of lines for active period of OVSB
0 - 15
3
13
ACYC
Automatic cycle setting enable
0 - 1
0
14
OHPOL
Specifies the polarity of output horizontal sync signal (OHSB)
0 - 1
0
15
OHSWD
Specifies the number of lines for active period of OHSB
0 - 15
4
16
VHSAME
0 - 1
1
17
OFLDP
Inverts the polarity of output field signal (OFLD)
0 - 1
0
18
HSCUT
0 - 1
1
19
SYNGO
Enables the generation of OVSB and OHSB
0 - 1
1
20
SRES
Clears OHSMON and OLNMON registers to 0
0 - 1
0
21
MGREN
0 - 1
1
22
OVFCHK
Resets the overflow check of line buffer
0 - 1
0
23
ATPOS
Enables automatic LNSEL setting
0 - 1
0
24
LNSEL
Sets line buffer read start position
0 - 7
3
25
OHSDLYL
Sets OHSB signal delay amount
0 - 255
0
26
OHSDLYU
Sets OHSB signal delay amount
0 - 15
0
27
OHSDLYEN
Enables OHSDLY set value
0 - 1
0
28
ATHDLY
Enables automatic OHSDLY setting
0 - 1
0
L001SCALE
No.
Name
0
VSCLEN
Selects enable/disable of vertical interpolation
0 - 1
1
1
VBEN
0 - 1
0
2
VDECSFT
0 - 1
0
3
ODDINI
Specifies vertical scaling initial value for odd field
0 - 7
0
4
EVEINI
Specifies vertical scaling initial value for even field
0 - 7
4
5
HSCKL
Specifies horizontal scaling factor
0 - 255
0
6
HSCKM
Specifies horizontal scaling factor
0 - 255
0
7
HSCKU
Specifies horizontal scaling factor
0 - 3
1
8
HSCK SCLEN
Selects enable/disable of horizontal enlarged interpolation
0 - 1
1
9
HSCK BEN
0 - 1
0
10
HSCK DECSFT
0 - 1
0
11
HKINI
Specifies horizontal enlargement initial value
0 - 7
0
12
HSRK SCLEN
Selects enable/disable of horizontal reduced interpolation
0 - 1
1
13
HSRK DECSFT
0 - 1
0
14
HSRKINI
Specifies horizontal reduction initial value
0 - 7
0
Item
Function
Data
Range
Data
Item
Function
Data
Range
Data
Enables OHS phase measurement and start point measurement of
output active area (OACT) in vertical direction
Outputs the output vertical sync signal (OVSB) simultaneously with
the output horizontal sync signal (OHSB) at all times
Disables the output of OHSB generated simultaneously with OVSB
Specifies decimal point place of factor in vertical interpolation table
Specifies decimal point place of factor in vertical enlarged
interpolation table
Specifies decimal point place of factor in horizontal reduced
interpolation table
L001ENH
No.
Name
0
SCENH
0 - 3
Table1
1
VCOFEN
Specifies vertical interpolation method
0 - 1
Table1
2
VCOFSEL
0 - 7
Table1
3
HCOFEN
Specifies horizontal enlarged interpolation method
0 - 1
Table1
4
HCOFSEL
0 - 7
Table1
5
HSRK COFEN
Specifies horizontal reduced interpolation method
0 - 1
Table2
6
SVDANEN
Enables vertical coring (lower threshold)
0 - 1
Table2
7
SVDAN  
0 - 31
Table2
8
SVCLPEN
Enables vertical coring (upper threshold)
0 - 1
Table2
9
SVCLP
0 - 31
Table2
10
SHDANEN
Enables horizontal coring (lower threshold)
0 - 1
Table2
11
SHDAN
0 - 31
Table2
12
SHCLPEN
Enables horizontal coring (upper threshold)
0 - 1
Table2
13
SHCLP
0 - 31
Table2
14
EYEN
Selects enable/disable of contour accentuation
0 - 1
Table2
15
EYMOD
Selects thin/thick of contour width
0 - 1
Table2
16
AOISEL
AOI control
0 - 3
Table2
17
EYD
Sets the degree of contour accentuation
0 - 7
Table2
18
YDANEN
Selects enable/disable of coring lower threshold
0 - 1
Table2
19
YDAN 
0 - 31
Table2
20
HICLPEN
Selects enable/disable of coring upper threshold
0 - 1
Table2
21
HICLPH
0 - 31
Table2
L001Y
No.
Name
0
SIGNA
0 - 1
0
1
OFSETA
0 - 127
0
2
SIGNB
0 - 1
0
3
OFSETB
0 - 127
0
4
GAINA
Makes linear correction (multiplication) to brightness
0 - 255
0
5
GAINB
Makes linear correction (multiplication) to brightness
0 - 255
0
6
BCUT
Clips BLUE to 0
0 - 1
0
7
GCUT
Clips GREEN to 0
0 - 1
0
8
RCUT
Clips RED to 0
0 - 1
0
9
RND
Enables 8 bits -> 6 bits forced round-down
0 - 1
0
10
DTH
Selects the mode for dithering
0 - 3
0
Item
Function
Data
Range
Data
Item
Function
Data
Range
Data
Specifies lower threshold of brightness gap range for vertical
contour accentuation
Specifies upper threshold of brightness gap range for vertical
contour accentuation
Specifies lower threshold of brightness gap range for horizontal
contour accentuation
Specifies upper threshold of brightness gap range for horizontal
contour accentuation
Specifies lower threshold of brightness gap range for contour
accentuation
Specifies upper threshold of brightness gap range for contour
accentuation
Makes linear correction (addition) to brightness with
positive/negative value
Makes linear correction (addition) to brightness with absolute value
Makes linear correction (addition) to brightness with
positive/negative value
Makes linear correction (addition) to brightness with absolute value
Data table selection (Table2)
Data table selection of vertical interpolation
Data table selection of horizontal interpolation
Page of 127