KF-42E200A, KF-50E200A, KF-55E200A - Sony TV Service Manual (repair manual). Page 12

Read Sony KF-42E200A / KF-50E200A / KF-55E200A Service Manual online

– 11 –
KF-42E200A/50E200A/55E200A
RM-GA007     RM-GA007      RM-GA007
3. Blinking count display of POWER/STANDBY indicator
- One blink is not used for self-diagnosis.
- Example
Diagnosis item
LED blinks
Lamp cover
3 times
Fan
4 times
LED ON : 0.3sec
LED OFF : 0.3sec
- Release of POWER/STANDBY indicator blinking
The POWER/STANDBY indicator blinking display is released by removing the plug from
the power or leaving for 2 minutes.
4. Self-diagnosis screen displays
- In cases of malfunctions where it is not possible to determine the symptom such as when
the power goes off occasionally or when the screen disappears occasionally, there is a
screen display on whether the malfunction occurred or not in the past (and whether the
detection circuit operated or not) in order to allow confirmation.
<Screen Display Method>
- Quickly press the remote command button in the following order from the standby state.
Channel
Vol
Be aware that this differs from
the method of entering the
service mode (Vol +).
LED OFF
3.0sec
DISPLAY
5
-
PO
TV
WER
 1
: LAMP_ERROR
0
 2
: LAMP_TEMP
0
 2
: TEMP_ERROR
0
3
: LAMP_COVER
0
 4
: FAN_ERROR
0
5
: LAMP_DRIVER
0
6
: LOWB_ERROR
0
7
: AUDIO_PROT
0
8
: D_OVP
0
 10 : ATSC_OVP
0
SELF CHECK
- Numeral "1" means a fault was detected one time
- Numeral "0" means that no fault was detected
Page of 110
Display

Click on the first or last page to see other KF-42E200A / KF-50E200A / KF-55E200A service manuals if exist.