KE-MX42A1, KE-MX42M1, KE-MX42N1, KE-MX42S1 - Sony TV Service Manual (repair manual). Page 12

Read Sony KE-MX42A1 / KE-MX42M1 / KE-MX42N1 / KE-MX42S1 Service Manual online

KE-MX42A1/MX42S1/MX42M1/MX42N1 (E)     2-1E
SECTION  2
ADJUSTMENTS
2-1. AGING
2-1-1. Measurement equipment
1.
Color analyzer (CA-100 manufactured by MINOLTA)
2.
Signal generator (ASTRO DESIGN VG-828D)
2-1-2. Aging condition
Power supply : 220 V (50Hz/60Hz)
Time
: More than 10 minutes
Temperature
: 22ºC ~ 28ºC
Luminance
: On aging mode setting
Note:
After aging, if power was shut down until W/B adjusutment, shall
be adjusted W/B after aging more than 30 second.
2-1-3. Measuring procedure
1.
Dab the W/B adjustment jig (CA-100) at the glass face of the
panel.
2.
Connect the Signal generator (VG-828D) to the VIDEO1
input terminal.
3.
Make the settings as follows.
• set the quality mode to PERSONAL.
• Set the PICTURE to MAX.
• Input All-white signal (70%).
There are 3 mode (COOL, NEUTRAL, WARM):
MODE
COLOR TEMPERATURE
W/B
COOL
13550K+OMPCD
4
NEUTRAL
9300K+8MPCD
2
WARM
8000K+8MPCD
1
*Operation Register
    Panel_Code 
⇒ FHP Tag
      R GAN
      G GAN
      B GAN
    Set any one of R, G and B to the data 255 when adjusting.
Adjustment target values:
MODE
X
Y
TOLERANCE
COOL
0.2684
0.2700
± 0.005
NEUTRAL
0.2838
0.2981
± 0.005
WARM
0.2944
0.3100
± 0.005