Read Sony KE-50XS910 Service Manual online
KE-50XS910 (UC) 2-1E
SECTION 2
ADJUSTMENTS
2-1. White Balance Adjustment
• Measurement equipment
1.Color analyzer (CA-100 manufactured by MINOLTA)
2.Signal generator (ASTRO DESIGN VG-828D)
2.Signal generator (ASTRO DESIGN VG-828D)
• Measuring procedure
1.Dab the W/B adjustment jig (CA-100) at the glass face of the
panel.
2.Connect the Signal generator (VG-828D) to the DVI terminal.
3. Input All-white signal (70%).
4. Make the settings as follows.
panel.
2.Connect the Signal generator (VG-828D) to the DVI terminal.
3. Input All-white signal (70%).
4. Make the settings as follows.
• set the quality mode to PRO.
• Set the PICTURE to MAX.
• SEt the color temp. be adjusted cool.
• Set the PICTURE to MAX.
• SEt the color temp. be adjusted cool.
5. Execute the following control with UART control from the
JIG PC.
JIG PC.
5-1. Set as follows:
R_GAIN_OFFSET = 31
G_GAIN_OFFSET = 31
B_GAIN_OFFSET = 31
(Unnecessary because NVM has been set)
G_GAIN_OFFSET = 31
B_GAIN_OFFSET = 31
(Unnecessary because NVM has been set)
5-2. Set as follows:
R_BIAS_OFFSET = 31
G_BIAS_OFFSET = 31
B_BIAS_OFFSET = 31
(Unnecessary because NVM has been set)
G_BIAS_OFFSET = 31
B_BIAS_OFFSET = 31
(Unnecessary because NVM has been set)
5-3. Set as follows:
SUBBRIGHT_R = 920
SUBBRIGHT_G = 880
SUBBRIGHT_B = 950
(Unnecessary because NVM has been set)
SUBBRIGHT_G = 880
SUBBRIGHT_B = 950
(Unnecessary because NVM has been set)
5-4. Set RKOF = 0, GKOF = 0, BKOF = 0.
5-6. Adjust RKOF and BKOF with the color values inTable
2 as the target.
5-7. When RKOF and BKOF cannot be adjusted:
(a) Return the smaller one of the adjusted values to 0.
(b) Readjust with the larger value and GKOF.
(b) Readjust with the larger value and GKOF.
5-8. When the following item is not satisfied after the above
adjustmetn, fix the smallest adjustment value at 0 and
readjust with the rest of two values.
(a) At least one of the value among RKOF, GKOF and
BKOF is 0.
readjust with the rest of two values.
(a) At least one of the value among RKOF, GKOF and
BKOF is 0.
5-9. Write the values determined as a result of the above
adjustment into RKOF, GKOF and BKOF.
5-10. Adjust PDRV_SUBCONT_R and
PDRV_SUBCONT_B with the color values among the
specified values in Table 1 as the target.
specified values in Table 1 as the target.
5-11. When there is a value that exceeds 512 after the
adjustment.
(a) Return the larger one of the adjusted values to 512.
(b) Readjust with the smaller value and
PDRV_SUBCONT_G.
(a) Return the larger one of the adjusted values to 512.
(b) Readjust with the smaller value and
PDRV_SUBCONT_G.
5-12. When the following items are not satisfied after the
above adjustment, fix the largest adjustment value at
512 and readjust with the rest of two values.
(a) All PDRV_SUBCONT_R, PDRV_SUBCONT_G
and PDRV_SUBCONT_B do not exceed 512.
(b) At least one of the value is 512.
512 and readjust with the rest of two values.
(a) All PDRV_SUBCONT_R, PDRV_SUBCONT_G
and PDRV_SUBCONT_B do not exceed 512.
(b) At least one of the value is 512.
5-13. Write the values determined as a result of the above
adjustment into PDRV_SUBCONT_R,
PDRV_SUBCONT_G and PDRV_SUBCONT_B.
PDRV_SUBCONT_G and PDRV_SUBCONT_B.
W/B standardized values:
6500K+8MPCD
8000K+8MPCD
9300K+8MPCD
10000K
13550K
W/B
0
1
2
3
4
X
0.3133
±0.003
0.2944
±0.003
0.2838
±0.003
0.2806
±0.003
0.2684
±0.003
Y
0.3297
±0.003
0.3100
±0.003
0.2981
±0.003
0.2883
±0.003
0.2700
±0.003
W/B
X
Y
COOL
13550K
NUETRAL
WARM
9300K+8MPCD
8000K+8MPCD
Comparison Table between the Color Temp name
and the adjustment color temperature:
and the adjustment color temperature:
5-5. Set as follows:
PDRV_SUBCONT_R = 512
PDRV_SUBCONT_G = 512
PDRV_SUBCONT_B = 512
(Unnecessary because NVM has been set)
PDRV_SUBCONT_G = 512
PDRV_SUBCONT_B = 512
(Unnecessary because NVM has been set)
6500K+8MPCD
8000K+8MPCD
9300K+8MPCD
10000K
13550K
W/B
0
1
2
3
4
X
0.3133
±0.004
0.2944
±0.004
0.2838
±0.004
0.2806
±0.004
0.2684
±0.004
Y
0.3297
±0.004
0.3100
±0.004
0.2981
±0.004
0.2883
±0.004
0.2700
±0.004
W/B
X
Y
Table 2:Target Color Values when adjusting
RKOF/GKOF/BKOF
6. Execute the following items with UART control from the
JIG PC.
6-1. Execute the method 3 with Color Temp. set to
neutral.
6-2. Execute the method 3 with Color Temp. set to
6-1. Execute the method 3 with Color Temp. set to
neutral.
6-2. Execute the method 3 with Color Temp. set to
warm.
7. Take off the W/B adjustment jig (MINOLTA, CA-100)
from the glass surface.
Click on the first or last page to see other KE-50XS910 service manuals if exist.