KE-50XS910 (serv.man2) - Sony TV Service Manual (repair manual). Page 40

Read Sony KE-50XS910 (serv.man2) Service Manual online

 
38
∗1 When Power supply unit is not Service JIG FY-0033, even if PD abnormality applies as above, 
all the lighting of LED is SD (shut down) flash 3 times.
∗2 If the unit cannot identify which protection circuit was activated, even if a power-down had been detected, the red LED may flash 15 times.
Category
PANEL-LED
Content
Unit's operation
STB
ON
SD
1 time
Communication failure of the 
panel-drive IC
Immediate shutdown
2 times
Communication failure of the 
module IIC
Immediate shutdown
3 times
Power decrease of the digital 
DC-DC converter
Immediate shutdown
4 times
Panel having high 
temperature
Shutdown 30 seconds 
after warning
PD
with
Power 
Supply 
Unit 
for 
Service 
JIG 
FY-0033
2 times
Panel-POWER SUPPLY
Immediate power-down
3 times
SCAN
Immediate power-down
4 times
SCAN-5V
Immediate power-down
5 times
Y-DRIVE
Immediate power-down
6 times
Y-DCDC
Immediate power-down
7 times
Y-SUS
Immediate power-down
8 times
ADDRESS
Immediate power-down
9 times
X-DRIVE
Immediate power-down
10 times
X-DCDC
Immediate power-down
11 times
X-SUS
Immediate power-down
12 times
DIGITAL-DCDC
Immediate power-down
15 times
UNKNOWN 
∗2
Immediate power-down
RED LED 
D4002
GREEN LED 
D4001
LED position of INTERFACE ASSY
INTERFACE ASSY
SIDE A
• Identification of locations having abnormality by the number of times the LEDs flash
On Shutdown and power-down
Shutdown
• Operation: When the microcomputer detects any abnormality, it forcibly turns off the unit.
• LED indication: The green LED of INTERFACE ASSY flashes.
Power-down
• Operation: When the unit is in emergency status, a protection circuit is activated, and the power is turned off.
• LED indication: The red LED of INTERFACE ASSY flashes.