DIAGNOSIS 
(Reliability Self Diagnostic Display Specifications for MEDIA RECEIVER)
The abnormal conditions are indicated by the following LED flashes.
       LED                        Status                        MEDIABOX                             PANEL
POWER/STBY   • 
⇔ 
• 
flashes alternately
             
-
                      
PANEL ALARM 
                                                                                                               (Not available for re-start)                            
                               Flashes (1Hz)                                -                        Defective for cable connection
                             
Flashes four times                         -                        Defective for power voltage of fan, 
                                                                                                               fan protection
                             
Flashes six times                +3.3V malfunction      Power protection on G board detected
                             
Flashes nine times              PANEL malfunction                         -
TIMER 
                 Flashes (1Hz)                     Defective for cable                           -     
                                                                           connection 
This unit has the following self diagnostic function. Refer to this table to 
 identify a defective point in case of any malfunction. 
                   
Problem   
                                                                            
Symptom
Mediabox
             Digital 3.3V malfunction   Shut down when Digital 3.3V becomes equal or under 0V. 
                              Defective for cable             The both White and Black interface cables are not connected
                               connection                           with the panel.
Panel 
                    PANEL ALARM
                               Defective for cable
                               connection                          The both White and Black interface cables are not connected 
                                                                           with the panel.
                             Fan malfunction
                              Power protector operation
*Operation count is based on WDT.