KE-50MR1, KE-50MR1E, KE-MR50A2, KE-MR50M1, KE-MR50M2, KE-MR50S2 - Sony TV Service Manual (repair manual). Page 62

Read Sony KE-50MR1 / KE-50MR1E / KE-MR50A2 / KE-MR50M1 / KE-MR50M2 / KE-MR50S2 Service Manual online

60
Voltage Adjustment (2)
VBW 
VBW 
VBW 
VBW 、
、 VP Adjustment  
VP Adjustment  
VP Adjustment  
VP Adjustment  
Measuring VP which is between TP327 and GND.
Adjust VP by VR1. (Tolerance:+/- 1.5 volt)
Measuring VBW which is between 
TP329 and TP330(–VW).
Adjust VBW by VR3. 
(Tolerance:+/- 0.5 volt)
VR3 (VBW)
VR1 (VP)
TP327 (VP)
TP329 (VBW)
NC
1
11
-VW
VSW
VBW
VP
8
7
10
5
3
4
2
NC
NC
NC
GND
9
GND
GND
6
In case of no measuring land on the 
board, please refer pin assignments.
Page of 70