KE-42TS2E, KE-42TS2U - Sony TV Service Manual (repair manual). Page 75

Read Sony KE-42TS2E / KE-42TS2U Service Manual online

 
 
  
 
 
 
 
72
   
6.2.6 Accumulation time reset 
            (1) 
The module is set according to the same to failure analysis procedure in clause 4.7. 
 
     
        (2) From the main menu, select Power-on time menu with the ↑ key or ↓ key and 
press the <ENTER> key.
 
 
 
 
 
 
 
 
 
 
         
 
  (3) From the Power-on time menu, select Operation hours with the  ↑ key or ↓ key and 
press the <ENTER> key. The Operation hour is input. *It is not possible to change in 
the energizing time according to the version of the service software. 
 
 
 
 
 
 
 
       
   
(4) "minute" is continuously input and < ENTER > key is pushed.   
           (5) "Second" is continuously input and < ENTER > key is pushed. 
 
       (6) Select RETURN with ↑key or  ↓key and press <ENTER> key to return to the menu 
screen. 
 
 
42H2   Main menu 
   Module information menu 
   Power ON menu 
   Problem analysis menu 
   Voltage adjustment menu 
** Accumulated power-on time menu 
   Logic board change menu 
 
   EXIT 
42H2  Accumulated power-on time menu 
** Running time indication:[hh:mm:ss]=
 
   RETURN 
   EXIT 
Page of 78
Display

Click on the first or last page to see other KE-42TS2E / KE-42TS2U service manuals if exist.