KE-37/42XS910 (UC)    2-1E
SECTION 2
ADJUSTMENTS
2-1. White Balance Adjustment
• Measurement equipment
1.Color analyzer (CA-100 manufactured by MINOLTA)
2.Signal generator (ASTRO DESIGN VG-828D)
• Measuring procedure
1.Dab the W/B adjustment jig (CA-100) at the glass face of the
   panel.
2.Connect the Signal generator (VG-828D) to the DVI terminal.
3. Input All-white signal (70%).
4. Make the settings as follows.
• set the quality mode to PRO.
• Set the PICTURE to MAX.
• SEt the color temp. be adjusted cool.
*Operation Register
    Panel_Code 
⇒ FHP Tag
      R GAN
      G GAN
      B GAN
    Set any one of R, G and B to the data 255   when adjusting.
COOL
13550K+OMPCD
NUETRAL
WARM
9300K+8MPCD
8000K+8MPCD
MODE
COLOR TEMPERATURE
W/B
4
2
1
COOL
0.2684
NUETRAL
WARM
0.2838
0.2944
MODE
X
TOLERANCE
0.005
0.2700
0.2981
0.3100
Y
±
0.005
±
0.005
±
There are 3 mode (COOL, NEUTRAL,
WARM):
Adjustment target values: