KE-32TS2E, KE-32TS2U - Sony TV Service Manual (repair manual). Page 75

Read Sony KE-32TS2E / KE-32TS2U Service Manual online

 
 
 
    
 
-72-
6.2.5  Logic board parameter forwarding 
(1) The module is set according to the same to failure analysis procedure in clause 4.7. 
The logic board before being exchanged is installed in the module. 
 
    
(2) From the main menu, select change Logic board menu with the ↑key or ↓key and press the <ENTER> key. 
 
 
 
 
 
 
 
 
 
    
(3) From the logic board change menu, select data copy with the ↑key or ↓key  and press the <ENTER> key. 
 Data is read before the Logic board is exchanged. 
 
 
 
 
 
(4) The Logic board is exchanged. 
 
(6) From the logic board change menu, select data paste with the↑key or ↓key and press the<ENTER> key. Data  
is written in the exchanged Logic board. 
 
 
 
 
 
 
(6) Select RETURN with ↑key or ↓key  and press <ENTER> key to return to the menu screen. 
 
 
 
 
 
32H2   Main menu 
   Module information menu 
** Power ON menu 
   Problem analysis menu 
   Voltage adjustment menu 
   Accumulated power-on time menu 
   Logic board change menu 
 
   EXIT 
32H2   Logic board change menu 
** Data copy (PDP -> Temp.FILE)/execute 
   Data Paste (PDP -> Temp.FILE)/execute 
   RETURN 
   EXIT 
32H2   Logic board change menu 
   Data copy (PDP -> Temp.FILE)/execute 
** Data Paste (PDP -> Temp.FILE)/execute 
   RETURN 
   EXIT 
Page of 79
Display