Read Sony KE-32TS2E / KE-32TS2U Service Manual online
-72-
6.2.5 Logic board parameter forwarding
(1) The module is set according to the same to failure analysis procedure in clause 4.7.
The logic board before being exchanged is installed in the module.
(2) From the main menu, select change Logic board menu with the ↑key or ↓key and press the <ENTER> key.
(3) From the logic board change menu, select data copy with the ↑key or ↓key and press the <ENTER> key.
Data is read before the Logic board is exchanged.
(4) The Logic board is exchanged.
(6) From the logic board change menu, select data paste with the↑key or ↓key and press the<ENTER> key. Data
is written in the exchanged Logic board.
(6) Select RETURN with ↑key or ↓key and press <ENTER> key to return to the menu screen.
32H2 Main menu
Module information menu
** Power ON menu
Problem analysis menu
Voltage adjustment menu
Accumulated power-on time menu
Logic board change menu
EXIT
Module information menu
** Power ON menu
Problem analysis menu
Voltage adjustment menu
Accumulated power-on time menu
Logic board change menu
EXIT
32H2 Logic board change menu
** Data copy (PDP -> Temp.FILE)/execute
Data Paste (PDP -> Temp.FILE)/execute
RETURN
EXIT
** Data copy (PDP -> Temp.FILE)/execute
Data Paste (PDP -> Temp.FILE)/execute
RETURN
EXIT
32H2 Logic board change menu
Data copy (PDP -> Temp.FILE)/execute
** Data Paste (PDP -> Temp.FILE)/execute
RETURN
EXIT
Data copy (PDP -> Temp.FILE)/execute
** Data Paste (PDP -> Temp.FILE)/execute
RETURN
EXIT
Click on the first or last page to see other KE-32TS2E / KE-32TS2U service manuals if exist.