Read Sony KDL-70X4500 (serv.man3) Service Manual online
KDL-70X4500 (K) 2-6
1) Power Error (R ED 2 tim es blink )
This indicates POWER Error, Low B error of 12V from G8 board. TV Micro (on AU board)
monitors pin79 and pin138 to detect POWER_ERR and shuts down chassis power to
Standby status.
monitors pin79 and pin138 to detect POWER_ERR and shuts down chassis power to
Standby status.
TV Micro pin138 Normal condition : Low / Error case : High
TV Micro pin79 i_lb_err< 0.7V(PW_ERR_LEV)
TV Micro pin79 i_lb_err< 0.7V(PW_ERR_LEV)
- Check 12V at CN 1000 on AU board. And F1001 on AU has 12V or not.
- Check G8 board.
- Check G8 board.
2) T-CON Error (R ED 5 tim es blink )
This indicates T-CON RDY signal error from timing controller of Panel module.
BE micro pin128 on FBU board detects it.
BE micro pin128 on FBU board detects it.
BE Micro pin128 Normal condition : High / Error case : Low
Replace Panel module.
3) B ack Light Error (R ED 6 tim es blink )
This indicates panel power circuit error such as inverter.
BE micro pin 78 on FBU board detects it.
BE micro pin 78 on FBU board detects it.
BE Micro pin 78 Normal condition : High / Error case : Low