KDL-70X4500 (HK) 2-4
2-4. SET REBOOTS
2-5. SELF DIAGNOSIS
2-5-1. RED LED BLINKS TABLE
TV micro (on ACW board) is monitoring if BE Micro & EMMA (on FBA board) are alive
or on abnormal status by watch dog timer. When BEM or EMMA has not boot up, TVM
try to re-start. We can see chassis reboot at this case. Check whether FBA board is
supplied with correct power or not.
or on abnormal status by watch dog timer. When BEM or EMMA has not boot up, TVM
try to re-start. We can see chassis reboot at this case. Check whether FBA board is
supplied with correct power or not.
- FBA board
- CN 2800 12V power and harness to G8 board.
- F2800, F4100, F4101, F4102, F5400, F7800, F7801 conduction.
- CN 2800 12V power and harness to G8 board.
- F2800, F4100, F4101, F4102, F5400, F7800, F7801 conduction.
If power rail has no problem, replace FBA board.
Power Error (watching 12V rail)
T-CON Error
[CCFL] Panel Inverter Error
[CCFL] Panel Inverter Error
[LED] GL board Error
Panel Temperature Abnormal Detection
Audio Abnormal Detection
FAN Error -> Not detect (reboot operation)
[CCFL] Panel Balancer Error
[LED-BL] SPI Error (Babylon Communication Error)
[LED-BL] SPI Error (Babylon Communication Error)
Contents
Display
(Self Diagnosis mode )
Red LED Blink
When self diagnosis happens, STBY (RED) LED blinks and
the history can be seen on display by self diagnosis mode.
the history can be seen on display by self diagnosis mode.
POW_ERR1
T_CON
BACKLITE
PANELTEMP
AUD_PROT
FAN_ERR
BALANCER
2
5
6
7
8
9
13