KDL-60EX640, KDL-60EX645 - Sony TV Service Manual (repair manual). Page 8

Read Sony KDL-60EX640 / KDL-60EX645 Service Manual online

KDL-60EX640/60EX645 v
CAUTIONS AND WARNINGS
SAFETY CHECK-OUT
After correcting the original service problem, perform the following safety 
checks before releasing the set to the customer:
1.  Check the area of your repair for unsoldered or poorly soldered 
connections. Check the entire board surface for solder splashes 
and bridges.
2.  Check the interboard wiring to ensure that no wires are “pinched” 
or touching high-wattage resistors.
3.  Check that all control knobs, shields, covers, ground straps and 
mounting hardware have been replaced. Be absolutely certain 
that you have replaced all the insulators.
4.  Look for unauthorized replacement parts, particularly transistors, 
that were installed during a previous repair. Point them out to the 
customer and recommend their replacement.
5.  Look for parts which, though functioning, show obvious signs of 
deterioration. Point them out to the customer and recommend 
their replacement.
6.  Check the line cords for cracks and abrasion. Recommend the 
replacement of any such line cord to the customer.
7.  Check the antenna terminals, metal trim, “metallized” knobs, 
screws and all other exposed metal parts for AC leakage. Check 
leakage as described in “Leakage Test”.
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and from all 
exposed metal parts to any exposed metal part having a return to chassis, 
must not exceed 0.5 mA (500 microamperes). Leakage current can be 
measured by any one of three methods.
1.  A commercial leakage tester.  
Follow the manufacturers’ instructions provided with the tester.
2.  A battery-operated AC milliammeter. 
3.  Measuring the voltage drop across a resistor by means of a VOM 
or battery-operated AC voltmeter. The “limit” indication is 0.75 V, 
so analog meters must have an accurate low voltage scale. Nearly 
all battery-operated digital multimeters that have a 2 VAC range 
are suitable. (see Figure A)
To Exposed Metal
Parts on Set
0.15 µF
Earth Ground
AC
Voltmeter
(0.75V)
Figure A. Use an AC voltmeter to check AC leakage.
HOW TO FIND A GOOD EARTH GROUND
The cover-plate retaining screw on most AC outlet boxes is at earth ground. 
Verify the AC outlet box retaining screw ground by connecting a 60W to 
100W incandescent (not a neon or fluorescent lamp) between the hot side 
of the receptacle and the retaining screw. Try both slots, if necessary, to 
locate the hot side on the line; the lamp should light at normal brilliance if 
the screw is at ground potential. (see Figure B)
Figure B. Checking for earth ground.
Trouble Light
AC Outlet Box
Page of 41