KDL-60EX640, KDL-60EX645 - Sony TV Service Manual (repair manual). Page 38

Read Sony KDL-60EX640 / KDL-60EX645 Service Manual online

KDL-60EX640/60EX645 30
SECTION 5 - UPDATES AND ADJUSTMENTS
COMPLETING SERVICE REQUIREMENTS WHEN 
REPLACING THE LCD PANEL
The following must be performed after replacing the LCD Panel. 
 
;
View the Status Information
 
;
Verify the Panel ID Code
 
;
Reset the Panel Operation Time
1.  TV must be in Standby mode.
2.  Press the following buttons on the 
Remote Commander 
within a second of each other: 
DISPLAY  
 Channel  5  
 Volume  +  
  POWER
Sound Adjustment
>>
Wide Band Tuning
>>
Range Scan…
>>
Self diagnosis history
>>
Status Information…
>>
LVDS Spectrum(%0)
<[
25
]>
DPMS
<[
Off
]>
Low of HPD
<[
5
]>
TVD_MCDONE_CNT
<[
20
]>
Demo Special
>>
Bypass AVI Info Detect
<[
On
]>
Panel Selection
<[
60_600D3LB4N
]>
UART Selection
No Log
SERIAL NUMBER EDIT
5000001
MODEL NAME EDIT
KDL-60EX645
[</>]Set [Home] Exit
Service Mode
VIEWING THE STATUS INFORMATION
After replacing the LCD Panel you MUST UPDATE the SOFTWARE to the
 
latest version. Verify the latest software is installed before proceeding to the 
service adjustments. 
Whenever the LCD Panel is replaced, the software must be updated so that 
the new panel syncs with the Main Board. If a message displays indicating 
the latest software is already installed, proceed to Resetting the LCD Panel 
to Update the Software.
3.  For instructions refer to the section 
“Viewing the Status 
Information” on page 25.
4.  Do one of the following:
a.  If the latest software is installed, proceed to 
Verifying 
the Panel ID Code.
b.  If the latest software is not installed, update the software 
and then proceed to 
Verifying the Panel ID Code.
VERIFYING THE PANEL ID CODE
5.  Press   until 
Panel Selection is selected.
Sound Adjustment
>>
Wide Band Tuning
>>
Range Scan…
>>
Self diagnosis history
>>
Status Information…
>>
LVDS Spectrum(%0)
<[
25
]>
DPMS
<[
Off
]>
Low of HPD
<[
5
]>
TVD_MCDONE_CNT
<[
20
]>
Demo Special
>>
Bypass AVI Info Detect
<[
On
]>
Panel Selection
<[
60_600D3LB4N
]>
UART Selection
No Log
SERIAL NUMBER EDIT
5000001
MODEL NAME EDIT
KDL-60EX645
[</>]Set [Home] Exit
Service Mode
Page of 41
Display