KDL-55W805B iii
CAUTIONS AND WARNINGS
3.  Measuring the voltage drop across a resistor by means of a VOM 
or battery-operated AC voltmeter. The “limit” indication is 0.75 V, so 
analog meters must have an accurate low voltage scale. Nearly all 
battery-operated digital multimeters that have a 2 VAC range are 
suitable. (see Figure A)
To Exposed Metal
Parts on Set
0.15 µF
Earth Ground
AC
Voltmeter
(0.75V)
Figure A. Use an AC voltmeter to check AC leakage.
HOW TO FIND A GOOD EARTH GROUND
The cover-plate retaining screw on most AC outlet boxes is at earth ground. 
Verify the AC outlet box retaining screw ground by connecting a 60W to 
100W incandescent (not a neon or fluorescent lamp) between the hot side of 
the receptacle and the retaining screw. Try both slots, if necessary, to locate 
the hot side on the line; the lamp should light at normal brilliance if the screw 
is at ground potential. (see Figure B)
Figure B. Checking for earth ground.
Trouble Light
AC Outlet Box
Page of 30