KDL-52X2000 (serv.man2) - Sony TV Service Manual (repair manual). Page 7

Read Sony KDL-52X2000 (serv.man2) Service Manual online

- 7 -
FIX
RM-ED006
FIX SELF DIAGNOSTIC SOFTWARE
The identification of errors within the FIX chassis is triggered in one of two ways :- 1: Busy or 2: Device failure to respond to IIC. In the event
of one of these situations arising the software will first try to release the bus if busy (Failure to do so will report with a continuous flashing
LED) and then communicate with each device in turn to establish if a device is faulty. If a device is found to be faulty the relevant device number
will be displayed through the LED (Series of flashes which must be counted).
Flash Timing Example : e.g. error number 3
StBy LED
ON
ON
OFF
OFF
LED  Error Code
Number of LED Flashes
Error Message
02
Panel Temperature Error
03
+B_OVP Error
04
Fan Error
06
LowB Error
07
Audio Protector Error
09
Panel Error
11
Converter Error
Note :
For a more detailed explanation on fault finding please refer to Section 3-4, trouble shooting.