KDL-46W705A, KDL-50W705A - Sony TV Service Manual (repair manual). Page 4

Read Sony KDL-46W705A / KDL-50W705A Service Manual online

KDL-46W705A/50W705A iii
CAUTIONS AND WARNINGS
LEAKAGE TEST
The AC leakage from any exposed metal part to earth ground and from all 
exposed metal parts to any exposed metal part having a return to chassis, 
must not exceed 0.5 mA (500 microamperes). Leakage current can be 
measured by any one of three methods.
1.  A commercial leakage tester.  
Follow the manufacturers’ instructions provided with the tester.
2.  A battery-operated AC milliammeter. 
3.  Measuring the voltage drop across a resistor by means of a VOM 
or battery-operated AC voltmeter. The “limit” indication is 0.75 V, so 
analog meters must have an accurate low voltage scale. Nearly all 
battery-operated digital multimeters that have a 2 VAC range are 
suitable. (see Figure A)
Parte de metal expuesta 
del televisor
0.15 µF 
Tierra física
Voltímetro
AC
(0.75V)
Figure A. Use an AC voltmeter to check AC leakage.
HOW TO FIND A GOOD EARTH GROUND
The cover-plate retaining screw on most AC outlet boxes is at earth ground. 
Verify the AC outlet box retaining screw ground by connecting a 60W to 
100W incandescent (not a neon or fluorescent lamp) between the hot side 
of the receptacle and the retaining screw. Try both slots, if necessary, to 
locate the hot side on the line; the lamp should light at normal brilliance if 
the screw is at ground potential. (see Figure B)
Figure B. Checking for earth ground.
Foco de Prueba
Tomacorriente de CA
Page of 28
Display