KDL-40XBR5, KDL-40XBR7, KDL-46XBR10, KDL-46XBR5, KDL-46XBR8, KDL-52XBR10, KDL-52XBR5, KDL-55XBR8, KDL-70XBR7, XBR-46HX909, XBR-52HX909 - Sony TV Service Manual (repair manual). Page 4

Read Sony KDL-40XBR5 / KDL-40XBR7 / KDL-46XBR10 / KDL-46XBR5 / KDL-46XBR8 / KDL-52XBR10 / KDL-52XBR5 / KDL-55XBR8 / KDL-70XBR7 / XBR-46HX909 / XBR-52HX909 Service Manual online

3
RS-232C PROTOCOL MANUAL
1. Communication Parameter
Communication system 
RS-232C
Synchronous system 
Asynchronous communication
Baud rate 
9600 bps
Character length 
8 bit
Parity None
Start bit 
1 bit
Stop bit 
1 bit
Flow control 
None
2. Pin Confi guration
No. Item 
Value
Header 
0x83: Enquiry
Category 
0x00 (fi xed)
3  Function 0xXX
Data1 
0xFF (fi xed)
Data2 
0xFF (fi xed)
Check Sum 
0xXX
(b) Enquiry (Host 
t Request of Read to Display)
Note: Enquiry commands are available for XBR-46HX909 and XBR-52HX909 only.
4. Communication Data Format
No. Item 
Value
Header 
0x8C: Control
Category 
0x00 (fi xed)
3  Function 0xXX
Length 
0xXX (=X+1 byte)
5 Data1 
0xXX
: : 
0xXX
: : 
0xXX
X+3 
Data (X) 
0xXX
X+4 
Check Sum 
0xXX
(a) Control (Host 
t Request of Write to Display)
 Check Sum:  The total from No.1 to No. X+3, when value exceeds 255,
   
1byte of data is confi rmed the bottom.
Display side (D-sub 9-pin male)
Host side (D-sub 9-pin)
Personal computer
KDL-52XBR5 etc.
- External view -
- External view -
5
4
3
2
1
6
7
8
9
5
4
3
2
1
6
7
8
9
Pin No.
1
2
3
4
5
6
7
8
9
Signal
NC
RD
TD
NC
GND
NC
NC
NC
NC
Pin No.
1
2
3
4
5
6
7
8
9
Signal
NC
RD
TD
NC
GND
NC
NC
NC
NC
3. Restriction for Communication
 Send control command after 20 seconds of power on.
 Strictly keep to send next command after receiving answer response from 
 Display.
 Set the command interval to 500ms or more.
 Value range for direct command is same as user can change by menu.
 When set is at standby mode, only receives Power ON command.
 To turn on the set, fi rst  set standby command as Enable. After this, the set 
  can receive Power ON command.
 Check Sum:  The total from No.1 to No. 5, when value exceeds 255, 1byte
   
of data is confi rmed the bottom.
No. Item 
Value
Header 
0x70: Answer
Answer* 
0x00:  Completed (Normal End)
 
 
0x01:  Limit Over
 
 
(Abnormal End-Exceed maximum value)
 
 
0x02:  Limit Over
 
 
(Abnormal End-Exceed minimum value)
  
0x03: 
Command Canceled (Abnormal end)
 
 
0x04:  Parse Error (Data Format Error)
Check Sum  0xXX
(c) Answer (Display 
t Response to host)
1
 Control answer
 0x00: Completed 
Normal response.
 
0x01: Limit Over 
The packets was received normally, but the 
   
 
data value was over the upper limit.
 
0x02: Limit Over 
The packets was received normally, but the 
   
 
data value was over the lower limit.
 
0x03: Command canceld 
The packet is received normally but either the
   
 
value of data is incorrect or request is not
   
 
permitted for the current host value.
 
0x04: Parse Error 
Received not defi ned format data or check
   
 
sum Error.
 Check Sum:  The total from No.1 to No. 2, when value exceeds 255, 1byte
   
of data is confi rmed the bottom.
Page of 10
Display

Click on the first or last page to see other KDL-40XBR5 / KDL-40XBR7 / KDL-46XBR10 / KDL-46XBR5 / KDL-46XBR8 / KDL-52XBR10 / KDL-52XBR5 / KDL-55XBR8 / KDL-70XBR7 / XBR-46HX909 / XBR-52HX909 service manuals if exist.