KDL-40X3500, KDL-46X3500, KDL-52X3500 - Sony TV Service Manual (repair manual). Page 8

Read Sony KDL-40X3500 / KDL-46X3500 / KDL-52X3500 Service Manual online

- 7 -
FIX2
RM-ED010
FIX2 SELF DIAGNOSTIC SOFTWARE
The identification of errors within the FIX2 chassis is triggered in one of two ways :- 1: Busy or 2: Device failure to respond to IIC. In the
event of one of these situations arising the software will first try to release the bus if busy (Failure to do so will report with a continuous
flashing LED) and then communicate with each device in turn to establish if a device is faulty. If a device is found to be faulty the relevant
device number will be displayed through the LED (Series of flashes which must be counted).
LED  Error Code
Number of LED Flashes
Display Error Message
Item Description
02
POW_OVP
Main Power Over Voltage Protection
03
POW_ERR1
Power Error
05
T_CON
T-CON Error
06
BACKLITE
Back Light Error (Panel Inverter)
07
TEMP ERR
Temperature Abnormal Detection
08
AUD PROT
Audio Abnormal Detection
09
FAN_ERR
Fan Error
13
BALANCER
Panel BALANCER Error
Flash Timing Example : e.g. error number 3
StBy LED
Note :
For a more detailed explanation on fault finding please refer to Section 3-8, trouble shooting.
FIX2 Working Hours checking
To check working hours of products it is necessary to enter
the following mode.
1. Place TV in Stand By mode (Enter following sequence)
2. The following menu will appear on screen
3. In bottom left corner you can see following digits (Block 1-
Block2-Block3)
Block 1 (5 digits) - Working Hours
Block 2 (5 digits) - Unused
Block 3 (5 digits) - Panel Hours
Note: Panel hours will be less than working hours due to “active
stand by” mode, working hours still increments, but panel hours
stops.
Page of 127
Display