KDL-40NX715, KDL-46NX715 (serv.man5) - Sony TV Service Manual (repair manual). Page 33

Read Sony KDL-40NX715 / KDL-46NX715 (serv.man5) Service Manual online

KDL-40NX715/46NX715 
 
28
SERVICE ADJUSTMENTS
22.  Press 
1
 until the 
001 DATA_TRANS_EXE item displays.
PEM
                      SERVICE
005
001
    LDRV_CHANGED
DATA_TRANS_EXE
                                  0
23.  For the 
DATA_TRANS_EXE item, press 
3
 to increase the 
data value to 1 to execute the update.
 
NOTE: A warning message indicating the TV cannot be 
turned off displays.
PEM
                     SERVICE
005
001
    LDRV_CHANGED
DATA_TRANS_EXE
                                  1
Data Value
DO NOT POWER OFF
Warning 
Message 
Displays
 
After the update is complete, the data value changes back to 
0 and a message indicating the data transter was successful 
displays.
24.  Proceed to “Verifying the Emitter Output Level”.
2-2-5.  VERIFYING THE EMITTER OUTPUT LEVEL
If necessary, the emitter LED output level can be increased or decreased.
25.  Press 
2
 until the 
009 3D category displays.
PEM
SERVICE
009
000 
EMIT_STR    
3D
0
Default
Data Value
26.  Using the table below, press 
3
 to increase or press 
6
 to 
decrease the data value.
DATA VALUE
SETTING
   0
Strong (Default)
   1
       Weak
 
27.  Press 
MUTING then press 
0
 to WRITE (Save) the changes.
28.  Exit Service Mode by turing the TV Power Off.
29.  Proceed to “Verifying the Model and Panel Information”.
Page of 40
Display