KDL-37M3000 - Sony TV Service Manual (repair manual). Page 11

Read Sony KDL-37M3000 Service Manual online

11
KDL-37M3000
KDL-37M3000
Viewing the Self Check Diagnostic List
1.  TV must be in standby mode. (Power off).
2.  Press the following buttons on the Remote Commander within a second of each other: 
 
DISPLAY   
Channel 
5   
Volume 
+  
  TV POWER .
 
The Self Check list displays. 
          
  This is the SAME as accessing Service Adjustments.
Results for all of the following diagnostic items are displayed at the bottom of the screen.  No error has occurred if the screen displays a “0”.
Software Version:
TVM: ER3.2
SUBM: 1.4
NVM: 1.2
Model Name:
Stored data from ADC 
calibration (from 
factory)
Diagnosis Information
Protection name and 
LED blinking times
How many times each 
protection has been 
activated
2: MAIN_POWER
0
6: BL (Back Light)
0
Í 0 indicates no error was detected
3: DC_ALERT1
0
7: TEMP
1
Í 1 indicates an error was detected
4: DC_ALERT2
0
7: Audio
0
5: DC_ALERT3
0
Clearing the Self Check Diagnostic List
1.  In Service Mode, press the Channel  8   
Channel 
0 .