Read Sony KDL-37M3000 Service Manual online
11
KDL-37M3000
KDL-37M3000
Viewing the Self Check Diagnostic List
1. TV must be in standby mode. (Power off).
2. Press the following buttons on the Remote Commander within a second of each other:
DISPLAY
Channel
5
Volume
+
TV POWER .
The Self Check list displays.
This is the SAME as accessing Service Adjustments.
Results for all of the following diagnostic items are displayed at the bottom of the screen. No error has occurred if the screen displays a “0”.
Software Version:
TVM: ER3.2
SUBM: 1.4
NVM: 1.2
TVM: ER3.2
SUBM: 1.4
NVM: 1.2
Model Name:
Stored data from ADC
calibration (from
factory)
calibration (from
factory)
Diagnosis Information
Protection name and
LED blinking times
LED blinking times
How many times each
protection has been
activated
protection has been
activated
2: MAIN_POWER
0
6: BL (Back Light)
0
Í 0 indicates no error was detected
3: DC_ALERT1
0
7: TEMP
1
Í 1 indicates an error was detected
4: DC_ALERT2
0
7: Audio
0
5: DC_ALERT3
0
Clearing the Self Check Diagnostic List
1. In Service Mode, press the Channel 8
Channel
0 .
Click on the first or last page to see other KDL-37M3000 service manuals if exist.