KDL-32EX705, KDL-40EX705, KDL-46EX705, KDL-52EX705, KDL-60EX705 (serv.man2) - Sony TV Service Manual (repair manual). Page 6

Read Sony KDL-32EX705 / KDL-40EX705 / KDL-46EX705 / KDL-52EX705 / KDL-60EX705 (serv.man2) Service Manual online

6
KDL-32EX705/40EX705/46EX705/52EX705/60EX705
KDL-32EX705/40EX705/46EX705/52EX705/60EX705
SECTION 1:  DIAGRAMS
1-1.  CIRCUIT BOARDS LOCATION
GE3A (KDL-32EX705/40EX705 Only)
GE2B (KDL-46EX705/52EX705 Only)
GE2A (KDL-60EX705 Only)
HMS2
SWITCH UNIT
HLR
BAL
1-2.  PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS INFORMATION
S : Measurement impossibility.
: B+line.
: B-line.  (Actual measured value may be different).
: signal path. (RF)
Circled numbers are waveform references.
The components identifi ed by shading and 
!
 symbol are critical for safety. Replace 
only with part number specifi ed. 
The symbol 
 indicates a fast operating fuse and is displayed on the component 
side of the board. Replace only with fuse of the same rating as marked.
NOTE: The components identifi ed by a red outline and a   mark contain confi dential 
information. Specifi c instructions must be adhered to whenever these components 
are repaired and/or replaced. 
See Appendix A: Encryption Key Components in the back of this manual. 
All capacitors are in μF unless otherwise noted. pF : μμF 50WV or 
less are not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise specifi ed.
All resistors are in ohms.  k
=1000, M=1000k
Indication of resistance, which does not have one for rating 
electrical power, is as follows:
 Pitch 
5mm 
     
 
Rating electrical power : 
1
/
 4 
W
1
/
 4 
W in resistance, 
1
/
10 
W and 
1
/
16 
W in chip resistance.
: nonfl ammable resistor
 : fusible resistor
 : internal component
 : panel designation and adjustment for repair
 : earth ground
 : earth-chassis
All variable and adjustable resistors have characteristic curve B, 
unless otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10M
 digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production 
tolerances.
All voltages are in V.
Page of 55
Display