SECTION 1:  DIAGRAMS
1-1.  CIRCUIT BOARDS LOCATION
1-2.  PRINTED WIRING BOARDS AND SCHEMATIC DIAGRAMS INFORMATION
All voltages are in V.
S : Measurement impossibility.
: B+line.
: B-line.  (Actual measured value may be different).
: signal path. (RF)
Circled numbers are waveform references.
The components identifi ed by shading and 
!
 symbol are critical for safety. Replace 
only with part number specifi ed. 
The symbol 
 indicates a fast operating fuse and is displayed on the component 
side of the board. Replace only with fuse of the same rating as marked.
NOTE: The components identifi ed by a red outline and a   mark contain confi dential 
information. Specifi c instructions must be adhered to whenever these components 
are repaired and/or replaced. 
See Appendix A: Encryption Key Components in the back of this manual. 
All capacitors are in μF unless otherwise noted. pF : μμF 50WV or 
less are not indicated except for electrolytics and tantalums.
All electrolytics are in 50V unless otherwise specifi ed.
All resistors are in ohms.  k
=1000, M=1000k
Indication of resistance, which does not have one for rating 
electrical power, is as follows: 
Pitch : 5mm 
 
 
    Rating 
electrical 
power 
1
/
 4 
W
1
/
 4 
W in resistance, 
1
/
10 
W and 
1
/
16 
W in chip resistance.
: nonfl ammable resistor
 : fusible resistor
 : internal component
 : panel designation and adjustment for repair
 : earth ground
 : earth-chassis
All variable and adjustable resistors have characteristic curve B, 
unless otherwise noted.
Readings are taken with a color-bar signal input.
Readings are taken with a 10M
 digital multimeter.
Voltages are DC with respect to ground unless otherwise noted.
Voltage variations may be noted due to normal production 
tolerances.
GD2 (KDL-46EX405) 
G2HE (KDL-40EX405/40EX406 ONLY)
G2LE (KDL-32EX305/32EX306/32EX405 ONLY)
SWITCH UNIT 
HLR 
BAL 