AZ1-EK SELF DIAGNOSTIC SOFTWARE
The identification of errors within the AZ1-EK chassis is triggered in one of two ways :- 1: Busy or 2: Device failure to respond to IIC. In the 
event of one of these situations arising the software will first try to release the bus if busy (Failure to do so will report with a continuous flash-
ing LED) and then communicate with each device in turn to establish if a device is faulty. If a device is found to be faulty the relevant device 
number will be displayed through the LED (Series of flashes which must be counted).
LED Error Codes and Descriptions
Self Diagnostic Screen Display
To bring up the self diagnostic screen display
i+
5
+
(ON SCREEN                            (DIGIT 5)                                (VOLUME +)                                  (TV)
   DISPLAY)
In standby mode, press the following sequence of buttons in quick succession on the remote commander as shown below:
Note that this differs from entering the service mode (volume   +   )
(TV POWER)
    (ON SCREEN
          DISPLAY)
         (DIGIT 5)
     (VOLUME -)
The following menu appears as shown below:
002     MAIN_POWE
003     AUD_PORT
003     DC_ALERT
005     BACK_POWE
006     BACKLITE
SELF CHECK
00000     00067     00000
                       [Menu]Exit
Back
<<
000
000
000
000
000
000 indicates no error was detected
001 indicates an error was detected
Number of LED
Flashes
Error Description
Possible Location
2
Main Power error.
G2HE/G2LE (Power Supply)
3
Audio error.
A (Main) Board
4
Balancer error.
LCD Panel
Balancer Board (ETC-Inverter MT Board)
5
TCON error.
LCD Panel
TCON Control MT Board
5
HFR error.
LCD Panel
6
Backlight error.
LCD Panel
Balancer Board (ETC-Inverter MT Board)
7
Temperature error.
A (Main) Board
Panel Operation Time by Hour (max 99999)
Boot Count (max 99999)
Total Operation Time by Hour (max 99999)
Clearing the self diagnostic list
Since the diagnostic results displayed on screen are not automatically cleared, always check the self diagnostic screen after you have com-
pleted the repairs to be sure you have cleared the result displat to “0”.
To exit the self diagnostic screen display
To exit the self diagnostic screen, turn off the power to the TV by pressing the Power button on the remote or the Power button on the TV set.
 
1. Error history and Error count: Press Channel 8 and then Channel 0.
 
2. Panel operation time: Press Channel 7 and then Channel 0.
Page of 41