11
KDL-26M4000/32M4000/37M4000/40M4000
KDL-26M4000/32M4000/37M4000/40M4000
LED Indicators
Diagnostic Item
Description
Number of times
TIMER/PIC OFF
LED flashes
Possible Location
Main Power
2 times
BM Board/BM4 Board
G1D Board (26" & 32")
G2D Board (37")
IP5Z Board (40")
DC Alert 1
3 times
BM Board/BM4 Board
DC Alert 2
4 times
BM Board/BM4 Board
DC Alert 3
5 times
BM Board/BM4 Board
Backlight
6 times
BM Board/BM4 Board
G1D Board (26" & 32")
G2D Board (37")
IP5Z Board (40")
ETC-Inverter MT Board
LCD Panel
Temp
7 times
BM Board/BM4 Board
Check Ventilation
Audio
8 times
BM Board/BM4 Board
G1D Board (26" & 32")
G2D Board (37")
IP5Z Board (40")
Viewing the Diagnostic List
1.  TV must be in standby mode. (Power off).
2.  Press the following buttons on the Remote Commander within a second of each other: 
 
DISPLAY   
Channel 
5   
Volume 
+  
  TV POWER .
 
The Self Check list displays. 
          
  This is the SAME as accessing Service Adjustments.
Results for all of the following diagnostic items are displayed at the bottom of the screen.  No error has occurred if the screen displays a “0”.
QR0.5-C510
Model Information: 32M4000  8000010
ADC Auto Calibration
Power On Time: 00001H
SMPTE
ColorBar100
ITU 709
Gain
424
1020
420
1020
456
16
8
1840
128
1592
128
1608
424
1020
422
1020
460
16
Offset
Cr
Y
Cb
ITU 601
VGA
2:MAIN POWER  0                       6:BL              0
3:DC ALERT1        0                       7:TEMP       1
4:DC ALERT2        0                       8:Audio      0
5:DC ALERT3        0
Gain
Offset
Gain
Offset
Factory Default
Indicates an error was detected
Indicates no error was detected
Model Information & Serial Number
Software Version
Power Time
Resets all settings
to the Factory Defaults
Diagnostic
List
Stored Data
from ADC calibration
(from factory)
Clearing the Diagnostic List
CAUTION: To remove the error indicator number you have to reset the settings back to the Factory Defaults. This action over-writes all customer 
settings.
 Before performing this reset, contact the customer to determine what adjustments they have made.  
1.  Using the remote commander, select Factory Default button.
2.  To reset the Diagnostic List, select Yes.
3.  To start Auto Program, select Yes.  NOTE: Allow 30+ minutes for Auto Program to complete.
4.  Using the customers information, reset their adjustments.
Page of 127