KDL-26BX320, KDL-26BX321, KDL-32BX320, KDL-32BX321, KDL-32BX420, KDL-37BX420, KDL-40BX420 - Sony TV Service Manual (repair manual). Page 10

Read Sony KDL-26BX320 / KDL-26BX321 / KDL-32BX320 / KDL-32BX321 / KDL-32BX420 / KDL-37BX420 / KDL-40BX420 Service Manual online

KDL-26/32/37/40BX320,321,420(AEP/UK)
10
SELF CHECK
BACK
<<
002 MAIN_POWER
000
003 DC_ALERT1   
000
003 AUDIO_PROT   
000
004 BALANCER_ERR   
000
005 TCON_ERR   
000
005 PANEL_ID_NVM_ERR   
000
006 BACKLITE_ERR   
000
007 TEMP_ERR   
000
12345‐67891‐23456
[Home] Exit
SELF DIAGNOSIS FUNCTION
[SELF DIAGNOSTIC SAMPLE SCREEN DISPLAY]
Error count
Item name
STBY LED flash time
Total operation time by hour
Boot count
Panel operation time by hour
Since the diagnostic results displayed on the screen are not automatically cleared, always check the self-diagnostic screen.
After you have completed the repairs, clear the result display to “0”.
Clearing the Self Check Diagnostic List
1. Error history and Error count :
Press the Channel 8 => Channel 0 .
2. Panel operation time :
Press the Channel 7 => Channel 0 .
Exiting the Self-diagnostic screen
To exit the Self Diagnostic screen, turn off the power to the TV by pressing the POWER button on the remote or the POWER button on the TV.