2. PRECAUTIONS
 
 
** To prevent the risks of unit damage, electrical shock and radiation, take the 
following safety, service, and ESD precautions.
 
 
2.1 Handling Precautions for Plasma Display 
 
  PDP module use high voltage that is 
dangerous to human. Before operating 
PDP, always check the dust to prevent 
circuit short. Be careful touching the 
circuit device when power is on. 
 
  PDP module is sensitive to dust and 
humidity. Therefore, assembling and 
disassembling must be done in no dust 
place.   
 
  PDP module has a lot of electric 
devices. Service engineer must wear 
equipment(for example , earth ring) to 
prevent electric shock and working 
clothes to prevent electrostatic. 
 
  PDP module use a fine pitch connector 
which is only working by exactly 
connecting with flat cable. Operator 
must pay attention to a complete 
connection when connector is 
reconnected after repairing. 
 
  The capacitor’s remaining voltage in 
the PDP module’s circuit board 
temporarily remains after power is off. 
Operator must wait for discharging    of 
remaining voltage during at least 1 
minute
 
 
2.2 Safety Precautions for Service (Handling, prevention of a electrical shock, 
measure against power outage, etc) 
 
( Safety Precautions ) 
 
  Before replacing a board, discharge forcibly 
The remaining electricity from board. 
  When connecting FFC and TCPs to the 
module, recheck that they are perfectly 
connected. 
  To prevent electrical shock, be careful not 
to touch leads during circuit operations. 
 
  To prevent the Logic circuit from being 
damaged due to wrong working, do not 
- 6 -
Page of 35