KD-34XBR2 - Sony TV Service Manual (repair manual). Page 7

Read Sony KD-34XBR2 Service Manual online

— 8 —
KD-34XBR2
Handling of Self-Diagnostic Screen Display
Since the diagnostic results displayed on the screen are not 
automatically cleared, always check the self-diagnostic screen 
during repairs. When you have completed the repairs, clear the 
result display to “0”.  Unless the result display is cleared to “0”, the 
self-diagnostic function will not be able to detect subsequent faults after completion of the repairs.
Clearing the Result Display
To clear the result display to “0”, press buttons on the Remote Commander sequentially when the diagnostic screen is displayed, as shown below:
 
ENTER
Channel 8
Quitting the Self-Diagnostic Screen
To quit the entire self-diagnostic screen, turn off the power switch on the Remote Commander or the main unit.
Self-Diagnostic Circuit
+B overcurrent (OCP) 
Occurs when an overcurrent (more 
than 6A) on the +B (135V) line 
is detected by R6598/R6591. It will 
cause Q6520 to turn on and force the 
AC relay to turn off through Q6532 
and Q6530.
+B overvoltage (OVP) 
Occurs when 1) overvoltage (more 
than +140V) on the +B (135V) line 
is detected by IC6505, or 2) an 
overvoltage (more than 7.5 V) on the 
unreg 7V line is detected by D6014.  
The AC relay will turn off through 
Q6532 and Q6530.
Vertical Defl ection Stopped 
Occurs when an absence of the 
Vertical defl ection pulse is detected by 
IC201. Power supply will shut down 
when waveform interval exceeds 2 
seconds. 
White Balance Failure
If the RGB levels* do not balance within 2 seconds after the power is turned on, this error will be detected by IC201. TV will stay on, but there 
will be no picture.
*(Refers to the RGB levels of the AKB detection Ref pulse that detects 1K).
Low B OCP/OVP
Occurs when set 5V is out.
Horizontal Defl ection Stopped
Occurs when either: 1) a +B overcurrent is detected (IC5007), or 2) overheating is detected (Thermistor TH5002).
To Bring Up Screen Test
In standby mode, press buttons on the Remote Commander 
sequentially, in rapid succession, as shown below:
DISPLAY   
 Channel  5   
 Sound volume  -   
 Power ON.
Numeral “0” means that no fault 
was detected.
Numeral “1” means a fault was 
detected one time only.
SELF DIAGNOSIS
2: +B OCP 
N/A
3: +B OVP 
N/A
4: VSTOP 
0
5: AKB 
1
6: LOWB 
0
7: H-STOP 
0
.
.
Page of 127
Display