7. Communication Rules
. When sending a command from CONTROLLER, the return data (CMD1 = 10 hex or CMD1 = each
category value, CMD2 = 03 hex) from PROJECTOR should be received first before sending the next
command. Even if the next command is sent before receiving the return data, since PROJECTOR will
not be able to receive that command, it does not return a response to CONTROLLER. Consequently, no
error code is also sent.
The following lists the approximate waiting times for PROJECTOR to return the return data after
CONTROLLER sends the command.
. When a communication error occurs, PROJECTOR ignores the data received until now, and set into the
reception standby state.
. For undefined commands or commends determined as invalid by PROJECTOR, PROJECTOR will
send the “NAK” return data to CONTROLLER .
. Take note that when data is written when the input signal of PROJECTOR is unstable, that data (value)
will not be incorporated.
. When INDEX specified SIRCS direct command (CMD1 = 17 hex) is transmitted, leave an interval of
45 mSec until the next transmission. (Do not return the return data (ACK, NAK) when the SIRCS
direct command is received.)
8. Approximate Return Waiting Times
Note: The times shown in this table are when communication is performed in the condition that it
will not be interrupted by some reason.
CMD1
00
00
01
01
01
03
03
CMD2
00
01
01
00
01
00
00
DATA1
_
_
00
00
00
00
01
DATA2
_
_
01, 02
05
05
_
_
TIME (mSec)
20
20
20
20
20
25
20