Set the destination when the MAIN PWB ASSY SERVICE was re-
placed.
2-1.  HOW  TO  CHANGE  THE  DESTINATION
Procedure
1.  Plug the AC adapter attached to the set into the DC IN 5V terminal 
on the rear panel of the set and insert the power cord into the socket. 
Press  the  1  (on/standby)  button  to  turn  off  the  power  once.
(The power switch LED on the set changes from green to orange.)
2.  With the [VIEW MODE] button and [MENU] button pressed, turn 
on  the  1  (on/standby)  button,  and  when  the  default  setting
screen(Fig. 2-1-1) appears, release the [VIEW MODE] button and 
[MENU] button.
3.  Check  that  the  model  name  displayed  on  the  side  of  “Model” 
name meets the following: 
A73  : DPF-A73
E73B  : DPF-E73 (BLACK)
E73W  : DPF-E73 (WHITE)
Note:Using [B] [b] buttons, move a yellow frame to the model    
 
name to be set.
6.  With  a  yellow  frame  moved  to  “Restore  all  setting”,  press  the 
[ENTER] button. (Fig. 2-1-3)
7.  The screen becomes green and the setting is complete.
8.  With green screen displayed, unplug the AC adapter from the DC IN 
5V terminal.
9.  Plug the AC adapter into the DC IN 5V terminal and turn on the 
power.
10.  Press the [MENU] button to display the Settings menu, and select 
“Initialize” to execute. (Fig. 2-1-5)
4.  Red characters of “Destination” show default setting of this set. 
(Fig.  2-1-1  shows  that  the  destination  has  been  set  to  U2) 
Using  [V]  [v]  [b]  [B]  buttons,  move  a  yellow  frame  to  the
destination to be set. (Fig. 2-1-1 shows that J1 has been selected as 
destination.)
5.  Press the [ENTER] button, and the characters will change to red, 
indicating that the selected destination was set. (Fig. 2-1-2) 
Model:
A73
J1
U2
CED
E33
KR2
CEP
E32
CN9
CA2
E73W
CEU
AU3
TW6
CEK
E37
JE3
HK4
AR2
Destination:
E73B
XXXXXXXX XXXXXXXX -X
Fig. 2-1-1
BR4
E35
Restore all setting
Model:
A73
J1
U2
CED
E33
KR2
CEP
E32
CN9
CA2
E73W
CEU
AU3
TW6
CEK
E37
JE3
HK4
AR2
Destination:
E73B
XXXXXXXX XXXXXXXX -X
Fig. 2-1-2
BR4
E35
Restore all setting
Model:
A73
J1
U2
CED
E33
KR2
CEP
E32
CN9
CA2
E73W
CEU
AU3
TW6
CEK
E37
JE3
HK4
AR2
Restore all setting
Destination:
E73B
XXXXXXXX XXXXXXXX -X
Fig. 2-1-3
BR4
E35
Fig. 2-1-4
Settings
Slideshow Settings
Auto power ON/OFF
Date/time settings
General Settings
System Information
Languege setting
Initialize
ENTER
BACK
/
Select
End
MENU
BACK
ENTER
Fig. 2-1-5
11.  Select “Reset” of “Initialize” to execute. (Fig. 2-1-6)
Initialize
Format internal memory
Initialize settings
ENTER
BACK
/
 Select
 Return
MENU
BACK
Fig. 2-1-6
ENTER
12.  Select  “Yes”  to  execute,  and  “Complete”  will  be  displayed, 
indicating that all the default settings have completed.   
(Fig. 2-1-7)
All settings will be
returned to fact roy default.
Yes
No
MENU
BACK
ENTER
Fig. 2-1-7
2-2.  CONFIRMATION OF DESTINATION
1.  Press the [MENU] button to display the menu, and if the language 
you selected is set, the setting has completed.
– ENGLISH –
The changed portions from
Ver.1.0 are shown in blue.
Ver.1.1 2010.03
Page of 7
Display

Click on the first or last page to see other DPF-A73 / DPF-E73 service manuals if exist.