MHS-FS1, MHS-FS1K, MHS-FS2, MHS-FS2K (serv.man2) - Sony Movie Service Manual (repair manual). Page 3

Read Sony MHS-FS1 / MHS-FS1K / MHS-FS2 / MHS-FS2K (serv.man2) Service Manual online

MHS-FS1/FS1K/FS2/FS2K_ADJ
5-3
Pressing the MENU button, the adjustment is completed and the initial screen for the adjustments appears.
To continue the adjustment, perform the operations mentioned from the next page.
Pressing the MENU button after the Bright Pixel adjustment finished normally, the screen will return to 
the normal mode. Be sure to turn off the power of the camera once.
When all adjustments are completed, press the ON/OFF (Power) button to finish the adjustment operations.
5-1-5. Setting the Adjustment Mode
1)  Download the firmware file “FS1_[][][]ADJ.zip”, “FS1K_[][][]ADJ.zip”, “FS2_[][][]ADJ.zip”, “FS2K_[][][]ADJ.zip” from the ESI homepage.
 
Uncompress the  “FS1_[][][]ADJ.zip”, “FS1K_[][][]ADJ.zip”, “FS2_[][][]ADJ.zip”, “FS2K_[][][]ADJ.zip” , then confirm that it includes the 
following item.
•  SDV5092C.bin
 
Note:
  Since the file name “SDV5092C.bin” is used on the above four models, pay attention to the applicable model from mistake.
2)  Save the uncompressed file “SDV5092C.bin” in the root directory of the slot named “BLOGGIE_SW”.
 
Note:
  Saving it in other directories causes a malfunction of program.
3)  With the camera turned off.
4)  Disconnect the USB cable from PC.
5)  Connect the equipment to be used by referring to “5-1-4 Connecting the Equipment”.
6)  Press the MOVIE/ENTER button (Key OK) for about five seconds and release when the LCD display turns on.
7)  After a few seconds, the LCD display will turn on and then show the adjustment mode screen.
8)  After a few seconds, the adjustment mode screen appears. (Fig. 5-1-4)
Key Left: AWB Adjust
Key Down: Bright Pix Adjust
Key Right: M360 Adjust
Key OK: Set Lang and Check Result
Key Up: AF Adjust
Fig. 5-1-4
5-2. CAMERA SECTION ADJUSTMENTS
5-2-1. AF Adjustment
 
(1) Far Focus Adjustment
Note:
 
When using the Flange back adjustment jig, take care of the following points:
•  For the illumination, use a light source such as an incandescent lamp or inverter type fluorescent light free from flickering.
•  Do not make an adjustment in the environment where fluorescent lamp flickering occurs even if the illuminance can be ensured with the room illumination only.
Use an incandescent lamp or inverter type fluorescent light at a place free from the influence of room illumination.
1)  Install the Flange back adjustment jig so that the distance between 
it and the front of lens of camera is 3cm or less.
Note:  Take care not to hit the Flange back adjustment jig when extend-
ing the lens.
2)  Make the height of Flange back adjustment jig and the camera equal.
3)  Check that the center of chart meets the center of shot image screen. 
Color temperature = 5000 ± 300K
Luminance: LV9 to 11
Be sure not to turn off the power during adjusting.
The adjustment finished normally.
Fig. 5-2-2
Far focus adjust...
Big search...
base pos:xxx
Far OK OOO
Pls change to Near Focus
The adjustment is complete.
The adjustment is finished abnormally.
Fig. 5-2-3
Far focus adjust...
Big search...
base pos:xxx
Far NG XXX
Pls ReAdjust Far Focus
Malfunction of Far Focus adjust-
ment
Adjustment order
Screen display
Fig. 5-2-1
Equipment required: Flange back adjustment jig
Flange back adjustment jig
3cm or less
Camera
Check that the camera is on the adjustment mode.
Confirm the indication
on the screen.
Finished normally.
Finished abnormally.
∗ For the setting procedure of the adjustment mode, refer to “5-1-5. Setting the Adjustment Mode” (Page 5-3).
Place the camera in front of the Flange back adjustment jig. (Fig. 5-2-1)
Press the Multi-selector button “ v (Key Up)”.
Press the
button (Key S1), then AF Adjustment (Far Focus Adjustment) starts.
In case of the adjustment is finished normally,
the adjustment completion indication appears
on the screen. (Fig. 5-2-2)
The adjustment will proceed to “Near Focus
Adjustment”, do not execute any key operation.
the following indication appears on the screen.
In case of the adjustment is finished abnormally,
(Fig. 5-2-3)
In this case, confirm the adjusting environment
and readjust.
Page of 7