6-12
HDR-UX1/UX1E_ADJ
3.
Origin Oscillation Check
Check the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
Subject
Not required
Measurement Point
Pin 5 of IC1301 (CHCK)
on VC- 456 board
Measuring Instrument
Frequency counter
Specified value
f = 40459541 
± 809 Hz (NTSC)
f = 31185000 
± 624 Hz (PAL)
Note: NTSC model: HDR-UX1
PAL model: HDR-UX1E
Switch setting
1) POWER ............................................................. MOVIE mode
Checking method:
1) Check that the frequency (f) satisfies the specified value.
Fig. 6-1-12
IC1301
IC1302
VC-456 BOARD (SIDE A)
5
Ver 1.2  2006.10
Page of 60