HDR-HC9, HDR-HC9E (serv.man4) - Sony Movie Service Manual (repair manual). Page 91

Read Sony HDR-HC9 / HDR-HC9E (serv.man4) Service Manual online

6-90
HDR-HC9/HC9E_ADJ
Initializing method:
Order Page Address Data
Procedure
1
7
01
C0
2
7
00
01
Press PAUSE (Write) button.
3
7
B0 to C6
Check that the data is “00”.
4
7
00
00
5
7
01
00
How to reset the flash error flag
When “FLASH error” (Self-diagnosis Code E:91:**) occurs, to
prevent any abnormal situation caused by high voltage, setting of
the flash is changed automatically to disabling charge and flash
setting.
After fixing, this setting needs to be deactivated. Connect the ad-
justment remote commander and perform the following process.
Order Page Address Data
Procedure
1
7
01
75
2
7
00
01
Press PAUSE (Write) button.
3
7
02
Check the data is “01”.
15. Record of Use Check (3)
Page 7
Address C8 to CD
Note 1:
 This data will not be erased (reset) when the lithium 3 V
power supply (MS-361 board BT801) is removed.
Note 2:
Check that the data of page: 0, address 10 is “00”.
Using method:
1) The record of use data is displayed at page: 7, addresses: C8 to
CD.
16. Record of Self-diagnosis Check
Page 7
Address B0 to C6
Note 1:
 This data will not be erased (reset) when the lithium 3 V
power supply (MS-361 board BT801) is removed.
Note 2:
Check that the data of page: 0, address 10 is “00”.
Address
Self-diagnosis code
B0
“Repaired by” code (Occurred 1st time)   *1
B1
“Block function” code (Occurred 1st time)
B2
“Detailed” code (Occurred 1st time)
B4
“Repaired by” code (Occurred 2nd time)   *1
B5
“Block function” code (Occurred 2nd time)
B6
“Detailed” code (Occurred 2nd time)
B8
“Repaired by” code (Occurred 3rd time)   *1
B9
“Block function” code (Occurred 3rd time)
BA
“Detailed” code (Occurred 3rd time)
BC
“Repaired by” code (Occurred 4th time)   *1
BD
“Block function” code (Occurred 4th time)
BE
“Detailed” code (Occurred 4th time)
C0
“Repaired by” code (Occurred 5th time)   *1
C1
“Block function” code (Occurred 5th time)
C2
“Detailed” code (Occurred 5th time)
C4
“Repaired by” code (Occurred the last time)   *1
C5
“Block function” code (Occurred the last time)
C6
“Detailed” code (Occurred the last time)
*1 : “01” t “C”, “03” t “E”
Using method:
1) The past self-diagnosis codes are displayed at page: 7, address:
BC to C6. Refer to “1-5. SELF-DIAGNOSIS FUNCTION” of
“SERVICE MANUAL, LEVEL 2” for detail of the self-diag-
nosis code.
Address
C8
C9
CA
CB
CC
CD
Function
User initial power
Year
on date
Month
(BCD code)
Day
Final condensation
Year
occurrence date
Month
(BCD code)
Day
Remarks
After setting the clock, set the date of power on next
Page of 96
Display