HDR-HC9, HDR-HC9E (serv.man4) - Sony Movie Service Manual (repair manual). Page 10

Read Sony HDR-HC9 / HDR-HC9E (serv.man4) Service Manual online

6-9
HDR-HC9/HC9E_ADJ
2.
Modification of A, B, D, 1A, 1B Page Data
If the A, B, D, 1A, 1B page data has been initialized, change the
data of the “Fixed data-2” address shown in the following table by
manual input.
Processing before Modification A, B, D, 1A, 1B page data:
Order Page Address Data Procedure
1
0
01
01
2
0
10
00
3
7
01
38
4
7
02
FF
5
7
04
02
6
7
00
01
Press PAUSE (Write) button.
7
7
02
Check the data changes to
“01”.
Modifying Method:
1) If modification of data on pages A, B, D, set data: 00 to page:
0, address: 10, and then select pages A, B, D.
2) If modification of data on pages 1A, 1B, set data: 01 to page:
0, address: 10, and then select pages A, B.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
3) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note 1:
If copy the data built in the different model, the
camcorder may not operate.
4) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
5) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification A, B, D, 1A, 1B
page data:
Order
Page
Address
Data Procedure
1
0
10
00
2
7
01
38
Press PAUSE (Write) button.
3
7
02
FF
4
7
04
01
5
7
00
01
Press PAUSE (Write) button.
6
7
02
Check the data changes to
“01”.
7
2
00
29
8
2
01
29
Press PAUSE (Write) button.
Note 2:
If following symptoms occur after completing of the
“Modification A, B, D, 1A, 1B page data”, check that
the data of the “Fixed data-2” address of A, B, D, 1A, 1B
page are same as those of same model of same destina-
tion.
1) The power is shut off so that unit cannot operate.
3.
A Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
10
00
00
Test mode
11 to 17
Fixed data-1 (Initialized data)
18
Fixed data-2
19 to 2E
Fixed data-1 (Initialized data)
2F
Fixed data-2
30
Fixed data-1 (Initialized data)
31
Fixed data-2
32 to 7B
Fixed data-1 (Initialized data)
7C
7D
7E
Fixed data-2
7F
80 to 8F
Fixed data-1 (Initialized data)
90
E8
EA
91
0E
0D
92
DE
DD
Touch panel adj.
93
19
17
94 to FF
Fixed data-1 (Initialized data)
4.
B Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
of A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to D0
Fixed data-1 (Initialized data)
D1
00
00
D2
00
00
D3
00
00
D4
00
00
D5
00
00
USB Serial number data setting
D6
00
00
D7
00
00
D8
00
00
D9
00
00
DA to FF
Fixed data-1 (Initialized data)