HDR-CX500, HDR-CX500E, HDR-CX500V, HDR-CX500VE, HDR-CX505VE, HDR-CX520, HDR-CX520E, HDR-CX520V, HDR-CX520VE (serv.man2) - Sony Movie Service Manual (repair manual). Page 10

Read Sony HDR-CX500 / HDR-CX500E / HDR-CX500V / HDR-CX500VE / HDR-CX505VE / HDR-CX520 / HDR-CX520E / HDR-CX520V / HDR-CX520VE (serv.man2) Service Manual online

1-3
ENGLISH
JAPANESE
ENGLISH
JAPANESE
HDR-CX500/CX500E/CX500V/CX500VE/CX505VE/
CX520/CX520E/CX520V/CX520VE_L2
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
Block
Function
6
2
6
2
6
 
 
 
 2
6
 
 
 
 2
6
 
 
 
 2
6
 
 
 
 2
6
 
 
 
 2
6
 
 
 
 2
6
 
 
 
 2
9
1
9
2
9
4
9
4
9
4
9
5
9
6
Detailed
Code
0
0
0
1
0
2
0
3
0
4
1
0
1
1
1
2
2
0
0
1
0
1
0
0
0
1
0
2
0
0
0
0
Symptom/State
Handshake correction function does not
work well. (With PITCH angular
velocity sensor output stopped.)
Handshake correction function does not
work well. (With YAW angular velocity
sensor output stopped.)
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
communication abnormality among.
Image vibration correction during
handshake function does not work.
Shift lens initializing failure.
Shift lens overheating (Pitch)
Shift lens overheating (Yaw)
Abnormality of thermistor.
Abnormality when flash is being charged.
 Battery current value goes over the
max discharge current
Fault of writing or erasing the
flash memory
Internal flash memory fault
BGM data error
GPS hardware error
Map area mount error
Self-diagnosis Code
Repaired b
y:
Correction
Inspect PITCH angular velocity sensors (SE6601 on the MM-083
board) peripheral circuits.
Inspect YAW angular velocity sensors (SE6601 on the MM-083
board) peripheral circuits.
Refer to [1-4-1. E : 62 : 02 (Abnormality of IC for Steadyshot)
Occurred].
Inspect the steadyshot circuit (IC5501 on the VC-575 board).
Inspect the image vibraton angular velocity sensors
(SE9001 on the ST-217 board) peripheral circuits.
Replacement of lens block. If an error occurs again, replace the
VC-575 board. (Note 2)
Refer to [1-4-2. E : 62 : 11 (Shift Lens Overheating (Pitch))
Occurred].
Refer to [1-4-3. E : 62 : 12 (Shift Lens Overheating (Yaw))
Occurred].
Refer to [1-4-4. E : 62 : 20 (Abnormality of Thermistor)
Occurred].
Checking of flash unit or replacement of flash unit.
Check the remaining battery power because this symptom maybe
depended on the remaining battery level, and confirm whether or
not the symptom is occured after replacing the battery.
If the symptom is still occured, overhaul inspection is needed.
Check each output of DC/DC converter (IC4701) on VC-575
board connected to CK-217 board with FP-1127 board, and
connect DC/Batt harness (the minimum connection to periphery)
to VC-575 board.
Inspect the flash memory (IC8101 on the VC-575 board).
Inspect the flash memory  (IC8101 on the VC-575 board).
Inspect the flash memory  (IC8101 on the VC-575 board). If it is
OK, check the CPU (IC7501 on the VC-557 board).
CX500V/CX500VE/CX505VE/CX520V/CX520VE
Check whether the flexible board of the GPS module is broken,
and check whether it is inserted imperfectly. If there is no
problem the flexible board, inspect or replacement of the GPS
module.
CX500V/CX500VE/CX505VE/CX520V/CX520VE
Inspect or replacement of the MM-083 board.
Note 2 : When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment
items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the
handheld operation.
Page of 99
Display

Click on the first or last page to see other HDR-CX500 / HDR-CX500E / HDR-CX500V / HDR-CX500VE / HDR-CX505VE / HDR-CX520 / HDR-CX520E / HDR-CX520V / HDR-CX520VE (serv.man2) service manuals if exist.