HDR-CX220, HDR-CX220E, HDR-CX230, HDR-CX230E, HDR-CX280, HDR-CX280E, HDR-CX290, HDR-CX290E, HDR-CX320, HDR-CX320E, HDR-CX380, HDR-CX380E, HDR-CX390, HDR-CX390E, HDR-PJ220, HDR-PJ220E, HDR-PJ230, HDR-PJ230E, HDR-PJ320E, HDR-PJ380, HDR-P - Sony Movie Service Manual (repair manual). Page 8

Read Sony HDR-CX220 / HDR-CX220E / HDR-CX230 / HDR-CX230E / HDR-CX280 / HDR-CX280E / HDR-CX290 / HDR-CX290E / HDR-CX320 / HDR-CX320E / HDR-CX380 / HDR-CX380E / HDR-CX390 / HDR-CX390E / HDR-PJ220 / HDR-PJ220E / HDR-PJ230 / HDR-PJ230E / HDR-PJ320E / HDR-PJ380 / HDR-P Service Manual online

1-4
HDR-CX220/CX220E/CX230/CX230E/CX280/CX280E/CX290/CX290E/CX320/CX320E/CX380/CX380E/CX390/CX390E/PJ220/PJ220E/PJ230/PJ230E/PJ320E/PJ380/PJ380E/PJ390/PJ390E_L2
– ENGLISH –
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Inspect the lens block zoom MR sensor signal (pin eg of CN1003 on 
the VC-1010 board when zooming is performed when the zoom lever 
is operated, and the zoom motor drive circuit (IC5501 on the VC-1010 
board) when zooming is not performed.
E
6
1
1
1
The abnormalities in initialization of the focus 
lens and the abnormalities in initialization of 
the zoom lens occurred simultaneously.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
E
6
1
3
0
Reset position detection error on the stepper 
iris initializing
Turn the power on to open lens barrier. Disconnect the battery or power 
cord, and then connect again.
Confirm that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive IC in lens drive 
block (pin wg, wh of CN1003 on theVC-1010 board).
If iris blades work normally, confirm that they are closing completely 
and confirm following item.
・  Case of the iris blades do not close normally Replace the lens block).
・  Case of “E: 61: 30” is appeared and iris blades closed completely.
  Confirm that communication with lens block is normal.
・  Case of LCD is not displayed normally Check that connection be-
tween CN6702 on CM-1004 board and CN1008 on VC-1010 board 
by FP-2059 flexible board.
・  Case of LCD is displayed normally Replace the lens block.
E
6
2
0
0
Handshake correction function does not work 
well. (With PITCH angular velocity sensor 
output stopped.)
Inspect PITCH angular velocity sensors (SE7501 on the MS-1004 
board) peripheral circuits.
E
6
2
0
1
Handshake correction function does not work 
well. (With YAW angular velocity sensor 
output stopped.)
Inspect YAW angular velocity sensors (SE7501 on the MS-1004 board) 
peripheral circuits.
E
6
2
0
2
Abnormality of IC for steadyshot.
Refer to “1-5-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Oc-
curred”.
E
6
2
0
3
IC for steadyshot and micro controller com-
munication abnormality among.
Inspect the steadyshot circuit (IC5501 on the VC-1010 board).
E
6
2
0
4
Image vibration correction during handshake 
function does not work.
Inspect the image vibration angular velocity sensors (SE7701 on the 
VC-1010 board) peripheral circuits.
E
6
2
1
0
Shift lens initializing failure.
Replacement of lens block (Note 3). 
If an error occurs again, replace the VC-1010 board.
E
6
2
1
1
Shift lens overheating (Pitch)
Refer to “1-5-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Occurred”.
E
6
2
1
2
Shift lens overheating (Yaw)
Refer to “1-5-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Occurred”.
E
6
2
2
0
Abnormality of thermistor.
Refer to “1-5-4. E : 62 : 20 (Abnormality of Thermistor) Occurred”.
E
9
1
0
1
Abnormality when flash is being charged.
Check or replace the LED Flash/Video light or charging capacitor. 
(Note 4)
E
9
1
0
2
Abnormality of LED Video light.
Check or replace the LED Flash/Video light or charging capacitor. 
(Note 4)
E
9
1
0
3
Abnormality of LED Video light  Tempera-
ture detection.
Check or replace the LED Flash/Video light or charging capacitor. 
(Note 4)
E
9
2
0
1
Battery current value goes over the max 
discharge current
Check the remaining battery power because this symptom maybe 
depended on the remaining battery level, and confirm whether or 
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. Check each 
output of DC/DC converter (IC4301 on the VC-1010 board) with 
connected the DC JACK (J901) on the VC-1010 board. 
(The minimum connection to periphery)
E
9
4
0
0
Fault of writing or erasing the flash mem-
ory
Inspect the flash memory (IC8101 on the MM-102 board).
Note 3: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
Note 4: After repair, be sure to perform “1-6. PROCESS AFTER FIXING FLASH ERROR”.
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
9
4
0
1
Internal flash memory fault
Inspect the flash memory (IC8101 on the MM-102 board).
E
9
4
0
2
BGM data error
Check the CPU (IC1301 on the VC-1010 board).
E
9
5
0
0
GPS hardware error
Turn power off and turn power on again.
E
9
6
0
0
Map area mount error
Turn power off and turn power on again.
E
9
7
0
0
Projector  hardware error
Turn power off and turn power on again.
1-5.  METHOD OF COPING WITH SHIFT LENS ERROR (CX28[]/CX29[]/CX3[][]/PJ3[][] Model)
VC-1010 BOARD (SIDE A)
C5513
C5514
C5515
C5516
R5505
IC5501
Fig. 1
Measurement points on the VC-1010 board
*
*
Page of 32
Display

Click on the first or last page to see other HDR-CX220 / HDR-CX220E / HDR-CX230 / HDR-CX230E / HDR-CX280 / HDR-CX280E / HDR-CX290 / HDR-CX290E / HDR-CX320 / HDR-CX320E / HDR-CX380 / HDR-CX380E / HDR-CX390 / HDR-CX390E / HDR-PJ220 / HDR-PJ220E / HDR-PJ230 / HDR-PJ230E / HDR-PJ320E / HDR-PJ380 / HDR-P service manuals if exist.