FDR-AX100, FDR-AX100E, HDR-CX900, HDR-CX900E (serv.man2) - Sony Movie Service Manual (repair manual). Page 7

Read Sony FDR-AX100 / FDR-AX100E / HDR-CX900 / HDR-CX900E (serv.man2) Service Manual online

1-3
FDR-AX100/AX100E/HDR-CX900/CX900E_L2
– ENGLISH –
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
4
1
0
0
Wi-Fi Module Hardware Error
Check that connection between CN4102 on the VC-1027 board and 
CN2301 on the WF-1004 board by FP-2213 flexible board.
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens.)
Inspect the zoom MR sensor of lens block (pin el, ra of CN4001 on 
the VC-1027 board when zooming is performed when the zoom lever 
is operated, and the zoom motor drive circuit (IC1802 on the VC-1027 
board) when zooming is not performed.
E
6
1
1
1
The abnormalities in initialization of the focus 
lens and the abnormalities in initialization of 
the zoom lens occurred simultaneously.
Check both C: 32: 60 and E: 61: 10 of the self-diagnosis code.
E
6
1
3
0
Reset position detection error on the stepper 
iris initializing
Turn the power on to open lens barrier. Disconnect the battery or power 
cord, and then connect again.
Confirm that the iris blades in lens are working.
If iris blades do not working, check the iris motor drive IC in lens drive 
block (pin ef to ej of CN4001 on the VC-1027 board).
If iris blades work normally, confirm that they are closing completely 
and confirm following item.
・  Case of the iris blades do not close normally. Replace the lens block.
・  Case of “E: 61: 30” is appeared and iris blades closed completely.
  Confirm that communication with lens block is normal.
・ Case of LCD is not displayed normally. Check that connection 
between CN2001 on CM-1010 board and CN4004 on VC-1027 
board by FP-2204 flexible board.
・  Case of LCD is displayed normally. Replace the lens block.
E
6
1
3
1
Error in detection of the Reset Position at the 
time of Stepper IR Filter initialization.
Check that connection between CN4001 on the VC-1027 board and 
the lens block.
E
6
2
0
0
Handshake correction function does not work 
well. (With PITCH angular velocity sensor 
output stopped.)
Inspect PITCH angular velocity sensors (SE7701 on the MS-1022 
board) peripheral circuits.
E
6
2
0
1
Handshake correction function does not work 
well. (With YAW angular velocity sensor 
output stopped.)
Inspect YAW angular velocity sensors (SE7701 on the MS-1022 board) 
peripheral circuits.
E
6
2
0
2
Abnormality of IC for steadyshot.
Refer to “1-7-1. E : 62 : 02 (Abnormality of IC for Steadyshot) Oc-
curred”.
E
6
2
0
3
IC for steadyshot and micro controller com-
munication abnormality among.
Inspect the steadyshot circuit (IC1802 on the VC-1027 board).
E
6
2
0
4
Image vibration correction during handshake 
function does not work.
Inspect the image vibration angular velocity sensors (SE7711 on the 
VC-1027 board) peripheral circuits.
E
6
2
1
0
Shift lens initializing failure.
Replacement of lens block (Note 3). 
If an error occurs again, replace the VC-1027 board.
E
6
2
1
1
Shift lens overheating (Pitch)
Refer to “1-7-2. E : 62 : 11 (Shift Lens Overheating (Pitch)) Occurred”.
E
6
2
1
2
Shift lens overheating (Yaw)
Refer to “1-7-3. E : 62 : 12 (Shift Lens Overheating (Yaw)) Occurred”.
E
6
2
2
0
Abnormality of thermistor.
Refer to “1-7-4. E : 62 : 20 (Abnormality of Thermistor) Occurred”.
E
6
2
3
0
Abnormal CPU
Turn power off and turn power on again.
E
9
1
0
1
Abnormality when flash is being charged.
Check or replace the LED Flash/Video light or charging capacitor. 
E
9
1
0
2
Abnormality of LED Video light.
Check or replace the LED Flash/Video light or charging capacitor. 
E
9
1
0
3
Abnormality of LED Video light  Tempera-
ture detection.
Check or replace the LED Flash/Video light or charging capacitor. 
*
*
*
Note 3: When the lens block was replaced, start the Adjust Manual in the Adjust Station and execute the necessary adjustment items.
After the adjustment, make sure with the STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation.
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block
Function
Detailed
Code
E
9
2
0
1
Battery current value goes over the max 
discharge current
Check the remaining battery power because this symptom maybe 
depended on the remaining battery level, and confirm whether or 
not the symptom is occurred after replacing the battery. If the symp-
tom is still occurred, overhaul inspection is needed. Check each 
output of DC/DC converter (IC5100 on the VC-1027 board) with 
connected the DC JACK (J901) on the VC-1027 board. 
(The minimum connection to periphery)
E
9
4
0
0
Fault of writing or erasing the flash mem-
ory
Turn power off and turn power on again.
E
9
4
0
1
Internal flash memory fault
Turn power off and turn power on again.
E
9
4
0
2
BGM data error
Check the CPU (IC6000 on the VC-1027 board).
E
9
5
0
0
GPS hardware error
Turn power off and turn power on again.
E
9
5
0
1
Acceleration sensor HW error
Turn power off and turn power on again.
E
9
6
0
0
Map area mount error
Turn power off and turn power on again.
E
9
7
0
0
Projector  hardware error
Turn power off and turn power on again.
Note:  Functions of codes with * mark are not provided in this unit.
1-7.  METHOD OF COPING WITH SHIFT LENS ERROR
VC-1027 BOARD (SIDE A)
C1820
C1822
C1824
C1828
R1802
IC1802
Fig. 1
Measurement points on the VC-1027 board
*
*
*
*
*
*
Page of 28
Display

Click on the first or last page to see other FDR-AX100 / FDR-AX100E / HDR-CX900 / HDR-CX900E (serv.man2) service manuals if exist.