DCR-VX2200E (serv.man2) - Sony Movie Service Manual (repair manual). Page 71

Read Sony DCR-VX2200E (serv.man2) Service Manual online

6-70
DCR-VX2200E_ADJ
4-4.
SERVICE MODE
Note:
Before performing the adjustment, check the data of page:
0, address: 10 is “00”. If not, select page: 0, address: 00,
and set data “00”.
1.
Setting the Test Mode
Page A
Address 10
Data
Function
00
Normal
01
Forced camera power ON (CAMERA mode)
02
Forced VTR power ON (VCR mode)
03
Forced camera + VTR power ON
• Before setting the data , select page: 0, address: 01, and set data:
01.
• For page A, the data set will be recorded in the non-volatile
memory by pressing the PAUSE (Write) button of the adjust-
ment remote commander. In this case, take note that the test
mode will not be exited even when the main power is turned off
(8.4 Vdc).
• After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE (Write) button of the
adjustment remote commander. And select page: 0, address: 01,
and set data: 00.
2.
Emergence Memory Address
2-1. Emergence Memory Address (Mechanism
section)
Page C
Address F4 to FF
Address
Contents
F4
EMG code when first error occurs
F6
Upper: MSW code when shift starts when first error
occurs
Lower: MSW code when first error occurs
F7
Lower: MSW code to be moved when first error
occurs
F8
EMG code when second error occurs
FA
Upper: MSW code when shift starts when second
error occurs
Lower: MSW code when second error occurs
FB
Lower: MSW code to be moved when second error
occurs
FC
EMG code when last error occurs
FE
Upper: MSW code when shift starts when last error
occurs
Lower: MSW code when last error occurs
FF
Lower: MSW code to be moved when last error
occurs
When no error occurs in this unit, data “00” is written in the above
addresses (F4 to FF). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency ad-
dress (F4 to F7). In the same way, when the second error occurs,
the data corresponding to the error is written in the second emer-
gency address (F8 to FB).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (FC to FF).
Note:
After completing adjustments, be sure to initialize the data
of addresses F4 to FF to “00”.
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
3
71
01
Press PAUSE (Write) button.
3
3
03
FF
Press PAUSE (Write) button.
4
3
01
37
Press PAUSE (Write) button.
5
3
02
Check the data changes to
“00”.
6
3
03
Check the data changes to
“00”.
7
3
70
10
Press PAUSE (Write) button.
8
3
70
Check the data changes to
“11”.
9
0
01
01
Page of 80
Display