Read Sony DCR-TRV940 / DCR-TRV940E / DCR-TRV950 / DCR-TRV950E (serv.man4) Service Manual online
DCR-TRV940/TRV940E/TRV950/TRV950E
6-61
COVER
COVER
3-4.
VIDEO SYSTEM ADJUSTMENTS
Before perform the video system adjustments, check that the speci-
fied values of “66MHz/54MHz Origin Oscillation Adjustment” of
“1-3. CAMERA SYSTEM ADJUSTMENTS” is satisfied.
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
fied values of “66MHz/54MHz Origin Oscillation Adjustment” of
“1-3. CAMERA SYSTEM ADJUSTMENTS” is satisfied.
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
Adjusting Procedure:
1. Chroma BPF f
1. Chroma BPF f
0
adjustment
2. S VIDEO OUT Y level adjustment
3. S VIDEO OUT chroma level adjustment
4. VIDEO OUT level check
3. S VIDEO OUT chroma level adjustment
4. VIDEO OUT level check
1.
Chroma BPF f
0
Adjustment (DB-014 board)
Set the center frequency of IC7001 chroma band-pass filter.
Mode
CAMERA
Subject
All black
(Cover the lens with the lens cap)
(Cover the lens with the lens cap)
Measurement Point
CH1: Chroma signal terminal of
S VIDEO jack (75
S VIDEO jack (75
Ω
terminated)
CH2: Y signal terminal of
S VIDEO jack (75
S VIDEO jack (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
28
Specified value
A = 100 mVp-p or less
B = 200 mVp-p or more
B = 200 mVp-p or more
Note:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Check the that the burst
signal (B) is output to the
chroma signal terminal.
signal (B) is output to the
chroma signal terminal.
3
3
0C
04
Press PAUSE button.
4
C
28
Change the data and for
minimum amplitude of the
burst signal level (A). (The
data should be “00” to “0F”)
minimum amplitude of the
burst signal level (A). (The
data should be “00” to “0F”)
5
C
28
Press PAUSE button.
6
3
0C
00
Press PAUSE button.
7
Check the burst signal (B) to
the specified value.
the specified value.
8
0
01
00
Fig. 6-3-6
When the data of page: 3, address: 0C, is 00:
When the data of page: 3, address: 0C, is 04:
CH1
CH2
A
H
CH1
H
B
Click on the first or last page to see other DCR-TRV940 / DCR-TRV940E / DCR-TRV950 / DCR-TRV950E (serv.man4) service manuals if exist.