Read Sony DCR-TRV890E / DCR-TRV900 / DCR-TRV900E (serv.man5) Service Manual online
SERVICE MANUAL
Sony Corporation
Personal VIDEO Products Company
2000J1632-1
Printed in Japan ©2000.10
Published by Safety & Service Engineering Dept.
9-974-107-92
CORRECTION-2
Correct your service manual as shown below.
(PV00-010)
• Deleting of adjustment Items.
DCR-TRV890E/TRV900/TRV900E
RMT-811/812
US Model
Canadian Model
Korea Model
DCR-TRV900
AEP Model
UK Model
DCR-TRV890E/TRV900E
E Model
Hong Kong Model
Tourist Model
DCR-TRV900/TRV900E
Australian Model
Chinese Model
DCR-TRV900E
Page
5-10
INCORRECT
CORRECT
5.
ADJUSTMENTS
: Deleted portion.
2. IRIS & ND HALL Auto Adjustment
Checking method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 11, set data: 02, and press the PAUSE
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 11, set data: 02, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 6, address: 04, and set data: 03.
4) Select page: 6, address: 01, set data: 01, and press the PAUSE
4) Select page: 6, address: 01, set data: 01, and press the PAUSE
button.
5) Check the IRIS display data lies within the “88” to “8A” range.
6) Select page: 6, address: 01, set data: 03, and press the PAUSE
6) Select page: 6, address: 01, set data: 03, and press the PAUSE
button.
7) Check the IRIS display data lies within the “14” to “18” range.
8) Select page: 6, address: 01, set data: 00, and press the PAUSE
8) Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
9) Select page: 6, address: 1C, and set data: 02.
10) Check the ND display data lies within the “14” to “18” range.
11) Select page: 6, address: 1C, and set data: 03.
12) Check the ND display data lies within the “88” to “8A” range.
10) Check the ND display data lies within the “14” to “18” range.
11) Select page: 6, address: 1C, and set data: 03.
12) Check the ND display data lies within the “88” to “8A” range.
2. IRIS & ND HALL Auto Adjustment
Checking method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 11, set data: 02, and press the PAUSE
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 11, set data: 02, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 6, address: 04, and set data: 03.
4) Select page: 6, address: 01, set data: 01, and press the PAUSE
4) Select page: 6, address: 01, set data: 01, and press the PAUSE
button.
5) Check the IRIS display data lies within the “88” to “8A” range.
6) Select page: 6, address: 01, set data: 03, and press the PAUSE
6) Select page: 6, address: 01, set data: 03, and press the PAUSE
button.
7) Check the IRIS display data lies within the “14” to “18” range.
2000. 10
Display