5-49
DCR-TRV738E/TRV740/TRV740E/TRV840
3-3.
SERVO AND RF SYSTEM ADJUSTMENT
Before perform the servo and RF system adjustments, check that
the specified value of “54MHz/66MHz Origin Oscillation
Adjustment” of “VIDEO SYSTEM ADJUSTMENT” is satisfied.
And check that the data of page: 0, address: 10 is “00”. If not, set
data: 00 to this address.
Note:
NTSC model: DCR-TRV740/TRV840
PAL model: DCR-TRV738E/TRV740E
Adjusting Procedure:
1.
REEL FG adjustment
2.
PLL f
0
 & LPF f
0
 adjustment
3.
Switching position adjustment
4.
AGC center level and APC & AEQ adjustment
5.
PLL f
0
 & LPF f
0
 fine adjustment
6.
Hi8/Standrd8 switching position adjustment
7.
Cap FG duty adjustment
1. REEL FG Adjustment (VC-278 board)
Compensates the dispersion of the hall elements.
Measurement Point
Display data of page: 3, address: 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
17, 2F
Specified Value
00 or 01 or 04 or 05
Note:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Close the cassette compartment
without inserting a cassette.
2
0
01
01
Set the data.
3
3
01
1C
Set the data, and press PAUSE
button.
4
3
02
Check that the data changes to
“00”,
5
3
03
Check that the data is “00” or “01”
or “04” or “05”. (Note)
6
0
01
00
Set the data.
Note:
If the data is other value, adjustment has errors. (Take an appropriate
remedial measures according to the errors referring to the following
table.)
Data
Contents of defect
02, 03, 06, 07
T reel is defective
08, 09, 0C, 0D
S reel is defective
0A, 0B, 0E, 0F
S reel and T reel are defective
2. PLL f
0
 & LPF f
0
 Adjustment (VC-278 board)
Mode
VTR stop
Measurement Point
Display data of page: 3, address: 02, 03
Measuring Instrument
Adjustment remote commander
Adjustment Page
C
Adjustment Address
1F, 20, 22, 29
Specified Value
Data of page: 3, address: 02 is “00”.
Data of page: 3, address: 03 is “00”.
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
21
CA
Set the data, and press PAUSE
button.
3
3
01
00
Set the data, and press PAUSE
button.
4
3
01
30
Set the data, and press PAUSE
button.
5
3
02
Check that the data changes to
“00” with in 10 sec. (Note2)
6
3
03
Check that the data is “00”.
(Note2)
7
0
01
00
Set the data.
Note2:
If it isn’t satisfied, select page: C, address: 21, set the following
data, and press the PAUSE button, and repeat steps 3 to 6.
Setting data
When the data of page: C, address: 21 is “CA”.
CE
When the data of page: C, address: 21 is “CE”.
C6
When the data of page: C, address: 21 is “C6”.
D2
When the data of page: C, address: 21 is “D2”
C2
There are errors when it isn’t satisfied even if the above treatment is
done.
If bit2, bit3, bit4, bit5 or bit 6 of the data of page: 3, address: 03 is
“1”, there are errors. For the error contents, see the following table.
(For the bit values, refer to “5-4. SERVICE MODE”, “4-3. 3. Bit
value discrimination”.)
Bit value of page: 3,
Error contents
address: 03 data
bit 2 = 1 or bit 3 = 1
PLL f
0
 fine adjustment is defective
bit 4 = 1 or bit 5 = 1
PLL f
0
 adjustment is defective
bit 6 = 1
LPF f
0
 adjustment is defective
Page of 127