INITIALIZATION OF 8, A, B, C, D, E, F, 18, 1B,
1C, 1F PAGE DATA
Note:
If reading/writing data on pages 18, 1B, 1C, 1F, set data:
01 to page: 0, address: 10, and then select pages 8, B, C, F.
By this data setting, the pages 18, 1B, 1C, 1F can be se-
lected.
After the data reading/writing finished, return the data on
page: 0, address: 10 to “00”.
1-2-1.
Initialization of A, B, D, 1B Page Data
Note:
 Check that the data of page: 0, address: 10 is “00”.
1.
Initializing the A, B, D, 1B Page Data
Note 1:
If “Initialization of Pages A, B, D, 1B” is executed, all
data on pages A, B, D, 1B are initialized. (Only an indi-
vidual page cannot be initialized)
Note 2:
If the A, B, D, 1B page data has been initialized, the
following adjustments need to be performed again.
1)  Modification of A, B, D, 1B page data
Note 3:
NTSC model: DCR-TRV380/TRV480
PAL model: DCR-TRV480E
Adjustment Page
A
Adjustment Address
10 to FF
Adjustment Page
B
Adjustment Address
00 to FF
Adjustment Page
D
Adjustment Address
10 to FF
Adjustment Page
1B
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
7
04
Set the following data
00: NTSC model
01: PAL model
4
7
01
28
5
7
00
01
Press PAUSE button.
6
7
02
Check the data changes to
“01”.
7
Perform “Modification of A,
B, D, 1B Page Data”
2.
Modification of A, B, D, 1B Page Data
If the A, B, D, 1B page data has been initialized, change the data
of the“Fixed data-2” address shown in the following table by
manual input.
Modifying method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note 1:
If copy the data built in the different model, the
camcorder may not operate.
3) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after completing modification A, B, D, 1B page
data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE button.
Note 2:
If the following symptoms occur after completing of
the“Modification A, B, D, 1B page data”, check that the
data of the “Fixed data-2” addresses of A, B, D, 1B page
are same as those of the same model of the same desti-
nation.
1) The power is shut off so that unit cannot operate.