Read Sony DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man4) Service Manual online
DCR-TRV360/TRV361/TRV460/TRV460E/TRV461E
6-7
1-2.
INITIALIZATION OF 8, A, B, C, D, E, F, 18, 1B,
1C, 1F PAGE DATA
1C, 1F PAGE DATA
Note:
If reading/writing data on pages 18, 1B, 1C, 1F, set data:
01 to page: 0, address: 10, and then select pages 8, B, C, F.
By this data setting, the pages 18, 1B, 1C, 1F can be se-
lected.
After the data reading/writing finished, return the data on
page: 0, address: 10 to “00”.
01 to page: 0, address: 10, and then select pages 8, B, C, F.
By this data setting, the pages 18, 1B, 1C, 1F can be se-
lected.
After the data reading/writing finished, return the data on
page: 0, address: 10 to “00”.
IC4501
VC-345 BOARD (SIDE B)
156 : A
164 : B
164 : B
1-2-1.
Version Check
Due to the change of IC4501 (mechanism control), there are two
types of versions A and B.
The EEPROM data are different according to respective versions.
Also, the IC4501 version can be checked by a discrimination
method by the model name or by the adjusting remote commander.
types of versions A and B.
The EEPROM data are different according to respective versions.
Also, the IC4501 version can be checked by a discrimination
method by the model name or by the adjusting remote commander.
Note 1:
Changing the version does not make any changes in sche-
matic diagrams and the rest.
matic diagrams and the rest.
Note 2:
Make it sure to confirm the version after replacing
IC4501.
IC4501.
1.
Discrimination Method by the Model Name of
IC4501 (Mechanism Control)
IC4501 (Mechanism Control)
Fig. 6-1-6
2.
Discrimination Method by Adjusting Remote
Commander
Commander
Version check method:
1) Select page: 3, and address: FF.
2) The version of IC4501 can be checked from the displayed data.
1) Select page: 3, and address: FF.
2) The version of IC4501 can be checked from the displayed data.
Data
Version
11
A
12
B
Data change method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 1C, and input the data in the following table.
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 1C, and input the data in the following table.
Note:
To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each
time to set the data.
PAUSE button of the adjustment remote commander each
time to set the data.
3) Select page: 0, address: 01, and set data: 00.
Version
A
B
Address
D0
00
42
Click on the first or last page to see other DCR-TRV360 / DCR-TRV361 / DCR-TRV460 / DCR-TRV460E / DCR-TRV461E (serv.man4) service manuals if exist.