DCR-TRV320, DCR-TRV320E, DCR-TRV320P, DCR-TRV420E, DCR-TRV520, DCR-TRV520E, DCR-TRV520P, DCR-TRV525, DCR-TRV620E, DCR-TRV720, DCR-TRV720E (serv.man3) - Sony Movie Service Manual (repair manual). Page 11

Read Sony DCR-TRV320 / DCR-TRV320E / DCR-TRV320P / DCR-TRV420E / DCR-TRV520 / DCR-TRV520E / DCR-TRV520P / DCR-TRV525 / DCR-TRV620E / DCR-TRV720 / DCR-TRV720E (serv.man3) Service Manual online

– 15 –
DCR-TRV320/TRV320E/TRV320P/TRV420E/TRV520/TRV520E/TRV520P/TRV525
TRV620E/TRV720/TRV720E
A
A: PSIG signal amplitude
V
6. Black Limit Adjustment (PD-133 board)
Set the common electrode drive signal level of LCD to the specified
value.
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin 4 of CN5502 (PSIG)
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
A6
Specified Value
A=8.15 
±
 0.08 Vp-p
7. Center Voltage Adjustment (PD-133 board)
Set the common electrode drive signal level of LCD to the specified
value.
Mode
Camera
Subject
Arbitrary
Measurement Point
Pin 3 of CN5502 (VG)
Measuring Instrument
Digital voltmeter
Adjustment Page
D
Adjustment Address
AB
Specified Value
A=7.00 
±
 0.03 Vp-p
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
2
0E
61
3
2
0F
Set the following data
5B (NTSC), 53 (PAL)
4
D
A6
Change the data and set the
voltage (A) to the specified value.
(The data should be “00” to “0F”)
5
D
A6
Press PAUSE button.
6
2
0E
00
7
2
0F
00
8
0
01
00
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
D
AB
Change the data and set the DC
voltage (A) to the specified value.
(The data should be “00” to “7F”)
3
D
AB
Press PAUSE button.
4
0
01
00
Fig. 5-3-31
Note:
NTSC model: DCR-TRV320/TRV320P
PAL model: DCR-TRV320E
Page of 16
Display